Endress+Hauser PROFIBUS Levelflex M FMP43 Operating Instructions Manual

Guided level-radar
Hide thumbs Also See for PROFIBUS Levelflex M FMP43:

Advertisement

Quick Links

Operating Instructions
Levelflex M FMP43
Guided Level-Radar
PROFIBUS PA
8
BA358F/00/en/07.07
No. 71041163
Valid as of software version
V 01.04.02

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser PROFIBUS Levelflex M FMP43

  • Page 1 Operating Instructions Levelflex M FMP43 Guided Level-Radar PROFIBUS PA BA358F/00/en/07.07 No. 71041163 Valid as of software version V 01.04.02...
  • Page 2 Here you can find measures you can take yourself to take remedial action against the fault. Æ → ä 105 Index You can find important terms and keywords on the individual sections here. Use the keyword index to find the information you need quickly and efficiently. Endress+Hauser...
  • Page 3 An overview of all the device functions can be found on → ä 100. An extensive description of all the device functions can be found in BA245F – "Description of Device Functions" on the CD-ROM provided. Operating Instructions can also be found on our homepage: www.endress.com Endress+Hauser...
  • Page 4 Brief overview Levelflex M FMP43 with PROFIBUS PA Endress+Hauser...
  • Page 5: Table Of Contents

    Installation ..... 12 Contact addresses of Endress+Hauser ... 93 Incoming acceptance, transport, storage ..12 Technical data .
  • Page 6: Safety Instructions

    The device is accompanied by separate “Ex documentation”, which is an integral part of this documentation. The installation regulations, connection values and safety instructions listed in this document must be observed. • Ensure that all personnel are suitably qualified. • Measuring point requirements with regard to measurement and safety must be observed. Endress+Hauser...
  • Page 7: Notes On Safety Conventions And Icons

    This may be a potential equalization line or a star grounding system depending on national or company codes of practice. Temperature resistance of the connecting cables t >85°C Indicates that the connecting cables have to withstand a temperature of 85 C at least. Endress+Hauser...
  • Page 8: Identification

    2.1.1 Nameplate The following technical data are given on the device nameplate: Order No Designation according to Directive 94/9/EC (see Order Information) and designation of protection ENDRESS+HAUSER Made in Germany Serial number LEVELFLEX-M D-79689 Maulburg Order Code: Ser.-No.: IP68 / NEMA 6P...
  • Page 9 D T12 Alu, coated IP68 NEMA 6P + OVP, D Separate terminal compartment, OVP = overvoltage protection Special version, to be specified Cable Entry: Cable gland M20 (EEx d > thread M20) Thread G 1/2 Thread NPT 1/2 Plug M12 Plug 7/8" Special version, to be specified Endress+Hauser...
  • Page 10 *CoC, EN 10204-3.1 material (316L wetted parts) inspection certificate Special version, to be specified FMP43- Complete product designation ⇓ Please enter probe length in mm or inch / 0.1 inch inch / 0.1 inch Probe length LN → ä 14 Endress+Hauser...
  • Page 11: Scope Of Delivery

    The device takes into account applicable standards and regulations which are listed in the EC declaration of conformity and thus meets the legal requirements of the EC Directives. Endress+Hauser confirms the successful testing of the device by affixing to it the CE mark.
  • Page 12: Installation

    Pack the measuring device in such a way as to protect it reliably against impact for storage and transportation. The original packing material provides the optimum protection for this. The permissible storage temperature is -20 °C to +80 °C. Endress+Hauser...
  • Page 13: Installation Conditions

    Installation Installation conditions 3.2.1 Dimensions Housing (see feature 80 in "Ordering information") - dimensions and materials Dimensions for the process connection and the probe type → ä 14. max. 110 ENDRESS+HAUSER F12 housing (Aluminium) L00-F12xxxx-06-00-00-en-001 max. 100 ENDRESS+HAUSER T12 housing...
  • Page 14 - 20 °C to 149 °C (3A Class. I, USP Cl. VI) ➂ Probe (see Feature 20 in "Ordering information) Material Version Option ➂ 0.8 μm mechanically polished K, M 316L (1.4435) 0.38 μm electropolished S, T Hastelloy C22 Special version available on request process connection (example) Endress+Hauser...
  • Page 15 DN70-76.1 (3") = 10 bar 83,4 Ø 90,9 SMS 1-½" PN25 with slotted nut* = 16 bar Ø 54,85 • EHEDG • 0.8 μm (tests passed, SMS 2" PN25 certificate pending) with slotted nut* = 16 bar 56,4 Ø 63,9 Endress+Hauser...
  • Page 16 • 0.38 μm electropolished Ø 42,9 NEUMO BioControl DN25 PN16* = 16 bar 30,4 30,4 1-1/2" 150lbs RF Flange ANSI B16.5* = 16 bar 17,5 • 0.8 μm 2" 150lbs RF 152,4 Flange ANSI B16.5* = 16 bar 19,1 Endress+Hauser...
  • Page 17 Levelflex M FMP43 with PROFIBUS PA Installation Process connection Designation Versions Approvals Option Thread M24 x 1.5 Accessory: weld-in adapter Weld-in adapter • 0.8 μm order number: 71041381 = 16 bar Ø 65 All metal parts used in the process in 316L (1.4435) Endress+Hauser...
  • Page 18: Installation Instructions

    Optimization options • Interference echo suppression: measurement can be optimized by electronically suppressing interference echoes. L00-FMP43xxx-17-00-00-xx-002 Note! You must ensure that the probe does not come into contact with the container wall, container bottom and tank internals. Endress+Hauser...
  • Page 19 Density [ρ] in kg/m 1000 (e.g. water) Probe diameter [d] in m 0.008 L = L (worst case) L00-FMP43xxx-16-00-00-xx-003 Bending torque [M] on rod probes 20.0 18.0 16.0 14.0 12.0 10.0 v=0.5m/s v=0.7m/s v=1.0m/s Probe length [ ] in meters L00-FMP43xxx-16-00-00-de-004 Endress+Hauser...
  • Page 20 • For mechanical reasons, the probe should be installed as vertically as possible. • The maximum mounting angle is – up to 1 m = 30° – up to 2 m = 10° – up to 4 m = 5°. L00-FMP43xxx-17-00-00-xx-006 Endress+Hauser...
  • Page 21 • The wall retainer can also be used for mounting in display panels. Please observe the dimensions on → ä 13 for the cutout. display plate wall ENDRESS+HAUSER Levelflex M 4 x Ø 8,5 Ø 5 ENDRESS+HAUSER Levelflex M pipe Ø...
  • Page 22: Post-Installation Check

    • Does the device correspond to specifications at the measuring point, including process temperature and pressure, ambient temperature, measuring range, etc.? • Are the measuring point number and labeling correct (visual inspection)? • Is the device adequately protected against rain and direct sunlight (→ ä 78)? Endress+Hauser...
  • Page 23: Cleaning Of The Probe

    Installation in the center of the tank • If the probe is mounted in the center of the tank, it may be necessary to use a second spray ball. The spray balls should then be mounted to the left and right of the probe. L00-FMP43xxx-17-00-00-xx-004 Endress+Hauser...
  • Page 24 (plug connection). The probe rod is screwed in the insulating bush with 4.5 Nm. • The O-rings r of the probe rod and adapter are now free accessible respectively changeable. The probe rod can be cleaned (autoclaved). O-ring order numbers, see → ä 86. Endress+Hauser...
  • Page 25 • screw the adapter into the container process connection together with the probe rod and tighten with 20 Nm • stick housing n with housing adapter on the adapter and bolt it with the grooved nut m - torque 20 Nm. Endress+Hauser...
  • Page 26: Wiring

    " Before connection please note the following: PROFIBUS devices are marked on the nameplate (1). The voltage is determined by the PROFIBUS standard and the Caution! ENDRESS+HAUSER Made in Germany LEVELFLEX-M desired safety concept. (see chapter 4.3). D-79689 Maulburg Order Code: Ser.-No.:...
  • Page 27 Levelflex M FMP43 with PROFIBUS PA Wiring Wiring in T12 housing " Before connection please note the following: ENDRESS+HAUSER PROFIBUS devices are marked on the nameplate (1). The LEVELFLEX M IP65 voltage is determined by the PROFIBUS standard and the...
  • Page 28 " ● PROFIBUS devices are marked on the nameplate (1). The voltage is determined by the PROFIBUS standard and the Caution! desired safety concept. (see chapter 4.3). ENDRESS+HAUSER Made in Germany LEVELFLEX-M D-79689 Maulburg Order Code: ● Connect potential matching line to transmitter earth terminal Ser.-No.:...
  • Page 29: Connecting The Measuring Unit

    • this protection is achieved by the use of other appropriate measures (external protection devices e.g. HAW262Z). Connection with M12 plug The Levelflex M PROFIBUS-PA sensor version with M12 plug is supplied ready wired and need only be connected to the bus by means of a suitable cord set. Endress+Hauser...
  • Page 30: Recommended Connection

    • Is the terminal assignment correct (→ ä 26 and → ä 27)? • Is the cable gland tight? • Is the M12 connector screwed tight? • Is the housing cover screwed tight? • If power is supplied: Is the device ready for operation and is the LCD display lit? Endress+Hauser...
  • Page 31: Operation

    (e.g. "medium property (003)") ➜ 5) Press ) once return to previous function (e.g. "tank shape (002)") ➜ Press ) twice return to Group selection 6) Press ) to return to Measured value display L00-FMP4xxxx-19-00-00-en-001 Endress+Hauser...
  • Page 32 The third digit numbers the individual functions within the function group: → • Basic setup • Tank properties • Medium property • Process propert. In the following section, the position is always given in brackets (e.g. "tank properties" (002)) after the function described. Endress+Hauser...
  • Page 33: Display And Operating Elements

    ENDRESS + HAUSER Symbol Main value Unit – Selection list Function groups -> Functions HOME F000 F001 F002 F003 F004 ... FG00 FG01 FG02 Help text FG03 FG04 +21mV FG05 FG06 Envelope FG07 curve 0.00 2.305m 10.00 L00-FMxxxxxx-07-00-00-en-001 Fig. 2: Display Endress+Hauser...
  • Page 34 Navigate to the right within a function group, confirmation Contrast settings of the LCD Hardware locking/unlocking After hardware locking, operation via display and communication is not possible! The hardware can only be unlocked via the display. A release code must be entered for this purpose. Endress+Hauser...
  • Page 35: Local Operation

    It is not possible to unlock the hardware by communication. All parameters can be displayed even if the device is locked. ⇒ ENDRESS + HAUSER Press simultaneously – ⇓ ⇓ The LOCK_SYMBOL appears on the LCD. Endress+Hauser...
  • Page 36 There is no need to change these parameters under normal circumstances and consequently, they are protected by a special code known only to the Endress+Hauser service organization. Please contact Endress+Hauser if you have any questions.
  • Page 37 • Sep. character (096) • End of probe (030) • Unlock parameter (0A4) • Level/ullage (040) • application par (0A8) • Linearization (041) • tag no (0C0) • Customer unit (042) • A complete “basic setup" (00) must be activated. Endress+Hauser...
  • Page 38: Displaying And Acknowledging Error Messages

    FieldCare FieldCare is Endress+Hauser's plant asset management tool based on FDT technology. With FieldCare, you can configure all Endress+Hauser devices and third-party devices that support the FDT standard. It is compatible with the following operating systems: WinNT4.0, Win2000 and WinXP.
  • Page 39 5.4.2 ToF Tool operating program The ToF Tool is a graphical operating software for devices from Endress+Hauser that work on the time-of-flight principle. It is used to support commissioning, data backup, signal analysis and device documentation. It is compatible with the following operating systems: WinNT4.0, Win2000 and WinXP.
  • Page 40: Profibus Pa Communication

    EEx ia IIC according to the FISCO model). The bus power is supplied by the segment coupler. On- site- as well as remote operation are possible. For detailed information on the PROFIBUS-PA standard refer to Operation Instructions BA 198F/00/en and the standards EN 50 170/DIN 19 245 (PROFIBUS-PA) and EN 50 020 (FISCO model). Endress+Hauser...
  • Page 41 DIP-switches 1 to 7 according to the following table: Switch No. Value in position "OFF" Value in Position "ON" The new address becomes valid 10 seconds after switching. It results a new device restart. Endress+Hauser...
  • Page 42 PA139700.gsd for devices with one analogue input block. This file supports the transmission of the main value. Transmission of a second cyclic value or a display value is not supported. When the universal database is used, the option "profile" must be selected in the function "Ident number" (061). Endress+Hauser...
  • Page 43 This is a value which can be transferred from the PLC to the Levelflex M in order to be shown on the display. FREE PLACE This module must be applied during configuration (see below), if the 2nd cyclic value or the display value are not to appear in the data telegram. Endress+Hauser...
  • Page 44 Die Output-Daten von der SPS für das Display am Gerät haben folgende Struktur: Index Data Access Format/Remarks Input Data 0, 1, 2, 3 Display value write 32 bit floating point number (IEEE-754) Status code for Display value write see "Status codes" Endress+Hauser...
  • Page 45 40 F0 00 00 (hex) = 0100 0000 1111 0000 0000 0000 0000 0000 (bin) (129-127) = (-1) x (1 + 2 = 1 x 2 x (1 + 0.5 + 0.25 + 0.125) = 1 x 4 x 1.875 = 7.5 Endress+Hauser...
  • Page 46 89 Hex GOOD LOW_LIM (alarm active) 8A Hex GOOD HI_LIM (alarm active) 8D Hex GOOD LOW_LOW_LIM (alarm active) 8E Hex GOOD HI_HI_LIM (alarm active) If a status other than "GOOD" is sent to the device, the display indicates an error. Endress+Hauser...
  • Page 47 If the application program is badly designed, however, this limit can be reached quickly, and the RAM will fail The Levelflex M supports MS2AC communication with two SAP´s. The Levelflex M does not support MS1AC communication. Endress+Hauser...
  • Page 48 Linearisation type UNSIGNED8 static Channel UNSIGNED16 static PV fail safe time FLOAT non-vol. Fail safe type UNSIGNED8 static Fail safe value FLOAT static Alarm Hysteresis FLOAT static HI HI Limit FLOAT static HI Limit FLOAT static LO Limit FLOAT static Endress+Hauser...
  • Page 49 Security locking V9H9 UNSIGNED16 non-vol. Factory reset V9H5 UNSIGNED16 non-vol. Descriptor OSTRING static Device message OSTRING static Device instal. date OSTRING static Gap reserved Ident number select V6H0 UNSIGNED8 static HW write protection UNSIGNED8 dynamic Gap reserved 42-53 Endress+Hauser...
  • Page 50 Up Down control UNSIGNED8 dynamic Up Down param OSTRING dynamic Bus address UNSIGNED8 dynamic Device SW No. UNSIGNED16 dynamic set unit to bus UNSIGNED8 static input value FLOAT+U8+U dynamic Select Main value UNSIGNED8 dynamic PA profile revision OSTRING constant Endress+Hauser...
  • Page 51 V2H1 UNSIGNED8 static Probe free V2H2 UNSIGNED8 static Probe length V2H3 FLOAT static Probe length setup V2H4 UNSIGNED8 static 163- Level/ullage V3H0 UNSIGNED8 static Linearisation mode V3H1 UNSIGNED8 static Customer unit V3H2 UNSIGNED16 static Table no. V3H3 UNSIGNED8 static Endress+Hauser...
  • Page 52 Display test V6H7 UNSIGNED8 static 206 - 218- Actual alarm V9H0 STRUCT dynamic Last alarm V9H1 STRUCT dynamic Clear last alarm V9H2 UNSIGNED8 static Reset V9H3 UNSIGNED16 static Operating code V9H4 UNSIGNED16 static Measured distance V9H5 FLOAT dynamic Endress+Hauser...
  • Page 53 For the digital output this value is rescaled in two steps: PV_SCALE_MAX from Transducer V0H0 block PV_SCALE_MIN AI_OUT OUT_SCALE OUT_SCALE (V6H2) L00-FMUx3xxx-05-00-00-en-001 In a first step, the main value is mapped to the interval [0;1]. PV_SCALE_MIN and PV_SCALE_MAX determine the limits of this mapping. Endress+Hauser...
  • Page 54 Thereby the new unit also becomes effective at the output. " Caution! If a linearisation has been carried out, it must be confirmed by the "Set unit to bus" (062) function in order to become effective at the digital output. Endress+Hauser...
  • Page 55: Commissioning

    Select the basic unit (this message appears the first time the device is switched ⇓ The current measured value is displayed ⇓ After pressing , you are taken to the group selection. This selection enables you to perform the basic setup Endress+Hauser...
  • Page 56: Basic Setup

    059 D = distance (distance flange / product) SD = safety distance display in 0A5 setting in 015 = level linearisation display in 0A6 extended calibr. L00-FMP43xxx-19-00-00-en-001 The basic setup is sufficient for successful commissioning in most applications. Endress+Hauser...
  • Page 57 • If the power supply fails, all preset and configured values remain safely stored in the EEPROM. " Caution! All functions are described in detail, as is the overview of the operating menu itself, in BA245F – "Description of Device Functions" on the CD-ROM supplied. Endress+Hauser...
  • Page 58: Basic Setup With Display Vu331

    (see installation in plastic containers). When using a metallic surface at the process connection, the "standard" option is sufficient! Note! In principle, it is preferable to use a metallic surface at the process connection! Endress+Hauser...
  • Page 59 – Mineral oils, fuels – Benzene, styrene, toluene 2.5 to 4 – Furan 4 m (354") – Naphthalene – Chlorobenzene, chloroform 4 to 7 – Cellulose spray – Isocyanate, aniline – Aqueous solutions > 7 – Alcohols – Acids, alkalis Endress+Hauser...
  • Page 60 Options: • Not modified • Modified Note! If "modified" was selected in the "probe length" (031) function, the probe length is defined in the next step. These settings result in an incorrect output signal for empty tanks. Endress+Hauser...
  • Page 61 After selecting "length too short" or "length too long", the calculation of the new value takes approx. 10 s. Function "empty calibr." (005) ⇒ ENDRESS + HAUSER – This function is used to enter the distance from the flange (reference point of the measurement) to the minimum level (=zero). Endress+Hauser...
  • Page 62 Function "full calibr." (006) ⇒ ENDRESS + HAUSER – This function is used to enter the distance from the minimum level to the maximum level (=span). 100% F = full calibration (= span) F max = E – upper blocking distance L00-FMP4xxxx-14-00-06-en-009 Endress+Hauser...
  • Page 63 Use this function for partially covered probes. Choose "manual" or "probe free" if the probe is free. • Mapping is carried out up to the currently measured echo • The range to be suppressed is suggested in the "range of mapping" (052) function It is wise to carry out a mapping even in this instance. Endress+Hauser...
  • Page 64 This function is used to start the interference echo suppression up to the distance entered in "range of mapping" (052). Options: • Off: no mapping is carried out • On: mapping is started Display (008) ⇒ ENDRESS + HAUSER – Endress+Hauser...
  • Page 65 ENDRESS + HAUSER – ⇓ After 3 s, the following message appears Note! After the basic setup, it is recommended to evaluate the measurement with the aid of the envelope curve ("envelope curve" (0E) function group) (→ ä 75). Endress+Hauser...
  • Page 66: Blocking Distance

    The blocking distance is preset to 0.2 m for rod probes. The blocking distance can be reduced if the probe is mounted flush with the wall or in a nozzle, max. 50 mm in height. When using a spray ball the blocking distance may not be smaller than 50 mm. Endress+Hauser...
  • Page 67 - 20 mm - 30 mm (water-based - 40 mm DK > 7 medium) - 50 mm oils and solvents - 60 mm DK = 2 100 mm 200 mm 200 mm 80 mm 40 mm 20 mm L00-FMP43xxx-05-00-00-en-001 Endress+Hauser...
  • Page 68: Envelope Curve With Vu331

    – Note! If the envelope curve mode is active on the display, the measured values are updated in a slower cycle time. Thus, it is advisable to leave the envelope curve mode after the measuring point has been optimized. Endress+Hauser...
  • Page 69: Function "Envelope Curve Display" (0E3)

    The active navigation mode is indicated by a symbol in the top left hand corner of the display. Horizontal Zoom mode: orizontal zoom in horizontal zoom out Move mode: oved to the left moved to the right Vertical Zoom mode: … - vertical zoom (4 steps) L00-FMPxxxxx-07-00-00-en-004 Endress+Hauser...
  • Page 70 Vertical zoom mode Press once more to switch to the vertical zoom mode. is displayed. You now have the following options: • increases the vertical scale. • decreases the vertical scale. The display icon shows the current zoom factor ( L00-FMPxxxxx-07-00-00-xx-003 Endress+Hauser...
  • Page 71: Basic Setup With The Tof Tool

    Basic setup step 1/6: • Status image • The TAG number can be entered. L00-FMP4xxxx-20-00-00-en-001 Note! • Each parameter that is changed must be confirmed with the RETURN key! • The "Next" button takes you to the next screen: Endress+Hauser...
  • Page 72 – medium properties (for a description, → ä 59) – process properties (for a description, → ä 60) l00-fmp4xxxx-20-00-00-en-002 Basic setup step 3/6: • Enter the application parameters: – end of probe (for a description, → ä 60) l00-fmp4xxxx-20-00-00-en-003 Endress+Hauser...
  • Page 73 – probe length (for a description, → ä 61) – determine length (for a description, → ä 61) l00-fmp4xxxx-20-00-00-en-004 Basic setup step 5/6: • Enter the application parameters: – empty calibration (for a description, → ä 61) – full calibration (for a description, → ä 62) l00-fmp4xxxx-20-00-00-en-005 Endress+Hauser...
  • Page 74 Levelflex M FMP43 with PROFIBUS PA Basic setup step 6/6: • Interference echo suppression takes place in this step • The measured distance and the current measured value are always displayed in the header • For a description, → ä 64) l00-fmp4xxxx-20-00-00-en-006.gif Endress+Hauser...
  • Page 75 Level echoes are indicated as positive signals in the envelope curve. Interference echoes can be both positive (e.g. reflections from internals) and negative (e.g. nozzles). The envelope curve, the map and the differential curve are used for the evaluation. Level echoes are searched for in the differential curve. Endress+Hauser...
  • Page 76 0.00 0.20 0.40 0.60 0.80 1.00 Differential curve = Envelope curve Mapping L00-FMP40xxx-05-00-00-en-025 6.8.2 User-specific applications (operation) For details of setting the parameters of user-specific applications, see separate documentation BA245F – "Description of Device Functions" on the CD-ROM supplied. Endress+Hauser...
  • Page 77: Maintenance

    They contain the related replacement instructions. All the spare parts kits which you can order from Endress+Hauser for repairs to the Levelflex M are listed with their order numbers on → ä 86 and 88. Please contact Endress+Hauser Service for further information on service and spare parts.
  • Page 78: Accessories

    For details refer to BA362F/00/A6. Order No.: 71041379 L00-FMP43xxx-06-00-00-xx-016 Calibration kit The calibration kit is used to regularly test the accuracy and reproducibility of the Levelflex M FMP43 level measurement device. For details refer to BA360F/00/en. Order No.: 71041382 Endress+Hauser...
  • Page 79: Remote Display And Operation, Fhx40

    20m/65ft; for HART 20m/65ft; for PROFIBUS PA/FOUNDATION Fieldbus Additional option: Basic version Mounting bracket, pipe 1"/ 2" FHX40 - Complete product designation To connect the FHX40 remote display, use the cables to suit the corresponding communication version of the device. Endress+Hauser...
  • Page 80: Commubox Fxa291

    Levelflex M FMP43 with PROFIBUS PA Commubox FXA291 The Commubox FXA291 connects Endress+Hauser field devices with CDI interface (= Endress+Hauser Common Data Interface) to the USB port of a computer or laptop. For details refer to TI405C/07/en. Note! For the following Endress+Hauser devices you need the "ToF Adapter FXA291" as an additional accessory: •...
  • Page 81: Troubleshooting

    Connect the plug Ready Display works? of the display. correctly Output current between The display is possibly defective. 3.6 …22mA ? Contact Endress+Hauser Service Not ok Output current Correct the Check cabling Current is ok? Ready < 3.6 mA ? (2 wire) cabling <...
  • Page 82: System Error Messages

    A251 feedthrough lost contact in the process feedthrough replace process feedthrough Endress+Hauser...
  • Page 83 A671 linearization ch1 not linearization table is in edit mode activate linearization table complete, not usable W681 current ch1 out of range current out of range check basic setup and linearization (3.8 mA to 21.5 mA) Endress+Hauser...
  • Page 84: Application Errors

    Noise level during the Repeat empty calibr. (005) once echo) after of echo loss the output is set to any value/ initialization phase too more. switching on the current. high. Caution! power supply Before confirmation change with to the edit mode. Endress+Hauser...
  • Page 85 (slope incorrect. properties selected → error in the entire Calibration not possible. 100% → measuring range) Selection expected → Select standard → Thresholds too high 2.) actual 1.) actual t → L00-FMP4xxxx-19-00-00-en-021 Medium properties Select lower medium properties. incorrect. Endress+Hauser...
  • Page 86: Spare Parts

    Spare parts Note! You can order spare parts directly from your Endress+Hauser Service organization by giving the serial number which is printed on the transmitter nameplate (→ ä 8). The corresponding spare part number also appears on each spare part. Installation instructions are given on the instruction card that is also supplied.
  • Page 87 52015586 Power unit, CSA, 90...250V AC (housing F12) for electronics, 4-wire 40 Display 52026443 Display/operating module VU331 65 Sealing kit 52013412 Sealing kit FMP4x 9.4.2 Spare parts Levelflex M FMP43 with housing F23 20 Cover 52018670 Cover F23 316L, sight glass, gasket 52018681 Cover F23 316L, gasket Endress+Hauser...
  • Page 88 -N o .: s s b e re a s u ic h r in g ra n 6 .. .3 x . 2 4 .. .2 > 7 0 ° C t > 8 5 ° C L00-FMP4xxxx-00-00-06-xx-002 Endress+Hauser...
  • Page 89 35 Terminal module / power unit 52013303 Terminal module Ex d, 2pole, 2-wire, PROFIBUS PA, FOUNDATION Fieldbus, T12 52018950 Terminal module EEx ia, 2pole, PROFIBUS PA, FOUNDATION Fieldbus, T12, OVP 40 Display 52026443 Display/operating module VU331 65 Sealing kit 52013412 Sealing kit FMP4x Endress+Hauser...
  • Page 90 U 16 m ax 4. ..2 ... 36 . 20 >7 0° t >8 5° C >7 0° t >8 5° C remote, compact, compact detachable detachable process connections hygienic connections as example: flange as example: clamp L00-FMP43xxx-00-00-06-de-001 Endress+Hauser...
  • Page 91 71043446 Adapter NEUMO BioControl DN25 PN16, 3.1 71043447 Tri-Clamp ISO2852 DN25-38 1..1-1/2", 3.1 71043448 Tri-Clamp ISO2852 DN40-51 2", 3.1 71043449 Tri-Clamp ISO2852 DN70-76.1 3", 3.1 71043450 Adapter SMS 2" PN25, 316L, 3.1 71043451 Adapter SMS 1-1/2" PN25, 316L, 3.1 Endress+Hauser...
  • Page 92 *CoC, EN10204-3.1 material (316L wetted parts) inspection certificate FMP43X1- Rod probe FMP43 w/o process connection. To connect to existing sensor body. 57 Sealing kit rod/process connection 71043452 Sealing kit FMP43 Kalrez, 2 pieces 71043453 Sealing kit FMP43 EPDM, 2 pieces Endress+Hauser...
  • Page 93: Return

    Software modifications Documentation 07.2007 V 01.04.02 Original software. BA358F/00/en/07.07 71041163 BA245F/00/en/07.07 71040937 Contact addresses of Endress+Hauser Contact addresses can be found on our homepage: www.endress.com/worldwide. If you have any questions, please do not hesitate to contact your Endress+Hauser representative. Endress+Hauser...
  • Page 94: Technical Data

    The measurements are carried out in accordance with EN 61298-3: temperature • Digital output (HART, PROFIBUS PA, FOUNDATION Fieldbus): – average T : 0.6 mm/10 K, max. ±3.5 mm over the entire temperature range -40 °C to +80 °C Endress+Hauser...
  • Page 95 Thick layers can dampen the signal and then reduce the measuring range. Heavy, uneven buildup, adhesion through crystallization, for example, can lead to incorrect measurement. In such instances, we recommend you use a non-contact measuring principle, or check the probe regularly for soiling. Endress+Hauser...
  • Page 96 -20 °C +130 °C Process pressure limits = 16 bar. The specified range may be reduced by the choice of process connection. See chapter "Dimensions" from → ä 13. Materials in contact with process ε r ≥ 1.6 Dielectric constant Endress+Hauser...
  • Page 97 See "Ordering structure" on → ä 8. Process connection See "Ordering structure" on → ä 8. Probe Note! The modular structure of the probe makes a simple possible exchanges of the process seals, the probe rod and the process coupling ring. Endress+Hauser...
  • Page 98 10.1.7 Certificates and approvals CE approval The measuring system meets the legal requirements of the EC guidelines. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. Certificates Correlation of safety instructions (XA) to the instrument:...
  • Page 99 The gap-free connections can be cleaned without residue using the usual cleaning methods. Many versions of Levelflex M meet the requirements of the 3A-Sanitary Standard No. 74. Endress+Hauser confirms this compliance by affixing the 3A symbol. Overfill protection SIL 2, for 4 to 20 mA output signal (see SD174F/00/en "Functional Safety Manual").
  • Page 100: Appendix

    Espanol x.xxx Italiano Nederlands Katakana (japanese) diagnostics present error previous error clear last error reset unlock parameter for reset code for enter code see manual see manual system parameter tag no. profile version protocol + sw-no. serial no. L00-FMP4xxxx-19-00-01-en-007 Endress+Hauser...
  • Page 101 . point , comma detection window measured dist. measured level application par. not modified modified reset distance unit download mode L00-FMP4xxxx-19-00-02-en-007 Endress+Hauser...
  • Page 102: Description Of Functions

    Reference point for "E" see above diagram, details → ä 56. The Levelflex possesses functions for interference echo suppression that can be activated by the user. They guarantee that interference echoes from internals and struts, for example, are not interpreted as level echoes. Endress+Hauser...
  • Page 103 • With a personal computer, FXA193 (RS232C) or FXA291 and ToF Adapter FXA291 (USB) and the operating software "ToF Tool - FieldTool Package" or "FieldCare". The ToF Tool is a graphical operating software for devices from Endress+Hauser (radar, ultrasonic, guided micro-pulse). It assists with commissioning, data backup, signal analysis and documentation of the measuring point.
  • Page 104 Appendix Levelflex M FMP43 with PROFIBUS PA Endress+Hauser...
  • Page 105: Index

    Nameplate ........8 Notes on safety conventions and icons ....7 Endress+Hauser...
  • Page 106 Levelflex M FMP43 with PROFIBUS PA Index Endress+Hauser...
  • Page 107 Erklärung zur Kontamination und Reinigung Please reference the Return Authorization Number (RA#), obtained from Endress+Hauser, on all paperwork and mark the RA# clearly on the outside of the box. If this procedure is not followed, it may result in the refusal of the package at our facility.
  • Page 108 www.endress.com/worldwide BA358F/00/en/07.07 No. 71041163 CCS/FM+SGML 6.0/ProMoDo 71041163...