[35] LINKS1000 Test Reporting Code

Cellular communications through the LINKS1000 Cellular
Alarm Transmitter will be tested periodically according to
the test transmission times programmed in Sections [17]
and [19]. The reporting codes programmed in Section
[35] will be transmitted during the cellular transmission
test.
When the cellular test transmission is completed, the
Automatic Test Code programmed in Section [10] will be
transmitted over the regular telephone line.
[36]

Keypad Lockout Control

Program two 2-digit numbers in this section.
The first entry determines how many invalid codes may be
entered before the keypad is locked out and will not
accept any further entries. Program a number from 00 to
99; 00 disables the keypad lockout function.
The second entry determines how long, in minutes, the
keypad will be locked out once the programmed
number of invlaid codes are entered. Program a time
from 00 to 99 minutes.
[90]

Installer's Lockout Enable

This feature is enabled by entering [90] while in the installer's
programming mode. A factory default (hardware or software)
will not reset the installer's code or the download access
code once this feature is enabled. A panel that has this
feature enabled will give a distinct audible indication upon
power-up. This indication is the phone line relay clicking 10
times. Make sure that your new installer's code has been
entered correctly before enabling this feature because there
is no way of re-entering the programming mode without the
new installer's code. Remember that even a reset to the
factory default will not change the installer's code back to the
default.

[91] Installer's Lockout Disable

Entering [91] when in the installer's programming mode will
disable the installer's lockout feature.
NOTE: Panels returned to DSC with the installer's lockout
feature enabled and no other apparent problems will be
subject to an additional service charge.