  • Page 1 Installation guide LenelS2 Readers - 5000 Series Standard...
  • Page 2 LenelS2 Readers - 5000 Series Standard 13.56 MHz - Technical specifications Operating frequency 13.56 MHz. NFC/BLE, MIFARE CSN 4 byte, MIFARE CSN 7 byte, MIFARE Classic, MIFARE Plus, MIFARE DESFire 0.6, MIFARE DESFire EV1, MIFARE DESFire EV2**, MIFARE DESFire EV3**, MIFARE Random CSN and iCLASS CSN 8 byte. Also supports other ISO 14443 A/B* compatible cards.
  • Page 3 LenelS2 Readers - 5000 Series Standard 13.56 MHz/125 kHz - Technical specifications Operating frequency 125 kHz & 13.56 MHz. NFC/BLE, Electromarine EM4200, HID® Proximity, MIFARE CSN 4 byte, MIFARE CSN 7 byte, MIFARE Classic, MIFARE Plus, MIFARE DESFire 0.6, MIFARE DESFire EV1, MIFARE DESFire EV2**, MIFARE DESFire EV3**, MIFARE Random CSN and iCLASS CSN 8 byte.
  • Page 4 LenelS2 Readers - 5000 Series Standard 13.56 MHz/125 kHz SF/2F Lenel Readers - 5000 Series - Technical specifications Standard 13,56MHz/125kHz SF/2F - Technical specifications Operating frequency 125 kHz & 13.56 MHz. Electromarine EM4200, HID® Proximity, MIFARE CSN 4 byte, MIFARE CSN 7 byte, MIFARE Random UID, MIFARE Classic, MIFARE Plus, MIFARE DESFire 0.6, MIFARE Operating frequency 125kHz &...
  • Page 5 Power Consumption Power Consumption LED-Brightness Current draw (idle) Current draw (peak) Model: LenelS2 Readers - 5000 Series LED-Bar Backlight 12 VDC 24 VDC 12 VDC 24 VDC Standard 13.56 MHz with keypad 50 mA 40 mA 147 mA 99 mA Standard 13.56 MHz with keypad Medium 50 mA...
  • Page 6 Package content: • 2pcs Installation screws • 1pc Installation plate • 2pcs Screw plugs • 1pc Reader module with • 1pc Cable strip front plate • 1pc Fixing screw • 1pc Front cover • 1pc Quick installation guide • 2pcs Terminal connector (8-pin) * Please note that all pictures in this manual are illustrations and do not represent the actual sizes and form of the components.
  • Page 7 ~20 cm In order to facilitate installation a cable length of 20 cm is recommended.
  • Page 8 Ensure that the installation plate is fixed in the correct direction, i.e. the arrows pointing upwards.
  • Page 9 Ensure that the area behind the tamper switch bulb of the installation plate is flat, to be able to push the bulb for correct tamper alarm functionality. If it is not flat enough, you will find accessories in this manual that will assist with improving this functionality.
  • Page 10 Options for tamper alarm protection The readers support both break off protection from the wall together with an opening protection of the reader, to give extended protection for the installation. If needed its possible to disable the break off protection with the red tray in the accessory bag.
  • Page 11 48 mm 21 mm 69 mm When installing directly to wall or door, use the recommended vertically aligned holes (as picture describes). If using other screws than the ones supplied with the reader, make sure to use a flat headed screw with a maximum height of 2.8 mm and a maximum diameter of 7.8 mm on the screw head.
  • Page 12 Tamper switch bracket (for gangbox socket), part no: LNL-R50000-TB When installing reader on a installation box, use the recommended horizontally aligned holes (as picture describes). If the tamperswitch functionality should be used a installation box tamperswitch bracket must be installed between the reader and the installation box. Utilize screws supplied with the installation box but make sure to use a screw and possible also washer with a maximum height of 2.8 mm and a maximum diameter of 7.8 mm.
  • Page 13 P2 - Black socket P1 - Blue socket Make sure to place the terminal connectors with the fastening screws facing towards you.
  • Page 14 LenelS2 Readers - 5000 Series Standard Blue Black Tamper GPO1 D1 Clock GPO2 D0 Data B/RX G-LED A/TX R-LED BZ CTRL K-LED RS485/ Clock/ Description Wiegand OSDP Data Tamper Tamper output General purpose I/O GPO1 GPO2 General purpose I/O Ground B/RX RS485 - A/TX...
  • Page 15 LenelS2 Readers - 5000 Series Standard Supervised F2/F Blue Black Tamper GPO1 D1 Clock GPO2 D0 Data B/RX G-LED A/TX R-LED BZ CTRL K-LED RS485/ Description Wiegand OSDP F/2F T/GPIO3 Tamper output / General purpose I/O General purpose I/O GPIO1 GPI/O2 General purpose I/O Ground...
  • Page 16 Reader Connection Reader Connection Supervised F/2F 2-state Supervised F/2F 2-state Reader Connection Supervised F/2F 2-state P4 - Blue Description F/2F SF/2F T/GPIO3 Tamper output / General purpose I/O GPIO1 General purpose I/O GPIO2 General purpose I/O Ground B/RX RS485 - / OSDP A/TX RS485 + / OSDP Ground...
  • Page 17 Reader Connection Reader Connection Supervised F/2F 2-state Supervised F/2F 4-state Reader Connection Supervised F/2F 2-state P4 - Blue Description F/2F SF/2F T/GPIO3 Tamper output / General purpose I/O GPIO1 General purpose I/O GPIO2 General purpose I/O Ground B/RX RS485 - / OSDP A/TX RS485 + / OSDP Ground...
  • Page 18 Make sure no excess connection cable is left in between the reader module and the installation plate. Use the enclosed cable strip to fix the cable in the cord grip. It is recommended to connect the the wires to the terminal connectors before tightening the cable strip.
  • Page 19 When installing the reader to the mounting plate ensure that the reader pin header contact perfectly aligns with the terminal connec- tor block.
  • Page 20 Mount the front cover as per the image above and make sure it is fitted correctly. In order to do so, allign and fit the top snap fastening, apply and main- tain pressure on the top of the front cover while sliding the front cover over the bottom snap fastening.
  • Page 21 To secure the front cover to the reader use the supplied fixing screw and fix it into the installation plate through the front cover.
  • Page 22 Opening Tool reader housing, part no: LNL-R50000-OT To open the reader, first remove the fixing screw and then detach the front cover from the installation plate by inserting the tip of the tool into the slot at the bottom of the front cover and move the tool upwards. This will release the front cover without damaging the front cover and/or the installation plate.
  • Page 23 Overview, programming of reader Setting the reader in programming mode see page: Configuring the Changing Resetting the reader authentication card OSDP secure channel. see page: see page: see page:...
  • Page 24 Setting the reader in programming mode BEEP ! Reading distance approximately 2 cm. Authentication Card, part no: LNL-C5000-AC In order to set the reader in programming mode, present the valid “Authentication Card” to the reader as shown. The reader will beep and start blinking to indicate that it is now in programming mode.
  • Page 25 Configuring the reader BEEP ! Reading distance approximately 2 cm. Configuration Card, part no: LNL-C5000-PCC 1: Set the reader in programming mode, see page: 23 2: Present the “Configuration Card” to the reader as shown. Keep the card within read- ing distance until the reader beeps and blinks in green.
  • Page 26 Changing authentication card BEEP ! Reading distance approximately 2 cm. Change Authentication Card, part no: LNL-C5000-PCAC 1: Set the reader in programming mode, see page: 23 2: Present the “CHANGE Authentication Card” to the reader as shown. Keep the card within reading distance un til the reader beeps and blinks in green.
  • Page 27 Resetting the OSDP secure channel. BEEP ! Reading distance approximately 2 cm. OSDP Installation mode Card, part no: LNL-C50000-OSDP 1: Set the reader in programming mode, see page: 23 2: Present the “OSDP Installation mode Card” to the reader as shown. Keep the card within reading distance until the reader beeps and blinks in green.
  • Page 28 Installing Secure Access Module • LNL-R50000-SAMTOOL: LenelS2 Readers - 5000 Series - SAM Tool to encode SIM cards HID OmniKey 6121 - has to be used with LNL-R50000-SAM application & LNL-R50000-SIM to program Secure Access Modules. • LNL-R50000-SAM: LenelS2 Readers - 5000 Series - SAM Manager software. Used together with LNL-R50000-SAMTOOL &...
  • Page 29 Accessories LenelS2 Readers - 5000 Series Standard...
  • Page 30 Stainless-steel spacer plate Spacer plate Std/Combi: LNL-R50000-SPS To ensure full function of the tamper switch in the LenelS2 Readers - 5000 Series reader, the spacer plate should be mounted behind the LenelS2 Readers - 5000 Series card reader’s back plate on uneven wall installations The acid resistant stainless-steel spacer plate can be used to ensure full function of the tamper switch in the reader, the spacer plate should be mounted behind the reader’s back plate on uneven wall installations or similar environments.
  • Page 31 Distance plate, standard Standard/Multi spacer Matte black, part no: LNL-R50000-SPB Standard/Multi spacer Matte white, part no: LNL-R50000-SPW The distance plate can be used for example when installing readers in environments where the installation surface is uneven or/and external wiring at the same side as the reader. Can also be used when mounting readers over installation boxes.
  • Page 32 Distance plate, large Standard/Multi spacer for vandal protection Matte black, part no: LNL-R50000-DPVPB Standard/Multi spacer for vandal protection Matte white, part no: LNL-R50000-DPVPW Used to install readers on an area where additional cover is needed to hide old installation holes or on uneven surfaces. Can also be used with external wiring on the same side as the reader.
  • Page 33 Distance plate, angled 10° Standard/Multi Angled spacer 10 degrees Matte white, art nr: LNL-R50000-DP10W Used to increase accessibility as well as visibility of the keypad.
  • Page 34 Distance plate, angled 10° * Screws and screw plugs included with accessory. Standard/Multi Angled spacer 10 degrees Matte black, art nr: LNL-R50000-DP10B Used to increase accessibility as well as visibility of the keypad. Using the horizontally aligned fixing points also allows for installation box fixing of the reader.
  • Page 35 Distance plate, angled 33° with QR code reader module. * Screws and screw Standard Angled spacer 33 degrees with QR plugs included with code add-on module, Matte black, part no: accessory. LNL-R50060-DP33B...
  • Page 36 From the QR code reader From the QR code reader there are four wires, power there are four wires, power and communication to be and communication to be connected at the readers connected at the readers terminal blocks. terminal blocks. Connection cable QR code module Connection cable QR code module Black wire GND...
  • Page 37 Distance plate, angled 33° * Screws and screw plugs included with accessory. Standard/Multi Angled spacer 33 degrees Matte black, art nr: LNL-R50000-DP33B Used to increase accessibility as well as visibility of the keypad. Recommended height is 900 mm (center of reader) above the ground/floor.
  • Page 38 Vandal protection * Screws and screw plugs included with accessory. Standard/Multi Vandal protection Matte black, part no: LNL-R50000-SPVPB The vandal protection is an accessory that shields the reader and helps it withstand violence by absorbing and redirecting external forces away from the reader.
  • Page 39 Distance plate, large + Vandal protection A recommended combination when external wiring is needed together with the vandal protection. Can also be used for covering up old installation holes.
  • Page 40 Climate- & Privacy protection * Screws and screw plugs included with accessory. Slimline and Standard/Multi Weather Cover transparent, part no: LNL-R50000-WR Slimline and Standard/Multi Weather Cover white, part no: LNL-R50000-WRW The transparent version LNL-R50000-WR is recommended to use for in- creased protection from rain and snow while still providing great visibility and accessibility in a slender format.
  • Page 41 Cleaning instructions Use compressed air in between the buttons to remove dust and dirt and after that isopropyl alcohol can be used with a piece of fabric to rub in between the buttons and the reader exterior.
  • Page 42 Contact info Carrier Fire & Security EMEA For all local contact details, please consult the Carrier Kelvinstraat 7 6003 DH – Weert, Fire & Security webpage: The Netherlands https://firesecurityproducts.com/en/contact.php Tel: +31 (0)495 58 30 00 Fax: +31 (0)495 55 00 42 Email: cs.edc@carrier.com...