Connecting to an External Device

Interface Connector

How to Connect an Interface Connector

When connecting the Module to an external device, you can use the supplied connector
plug. When wiring the Module, strip off approximately 7 - 8 mm of the covering for
the cable, and insert the bare wire by pressing the orange button on the connector plug.
Releasing the orange button after the wire is inserted to fix the cable. Compatible wires
are AWG 28 - 20.
RUN
Device
ID
CH0
CH1
CH2
CH3
D A I 1 2 - 4
Figure 3.1. Connecting an Interface Connector and Connectors That Can Be
Note!
Removing the connector plug by grasping the cable can break the wire.
DAI12-4(FIT)GY
Press this section to insert the
STATUS
wire material.
6
+
AG
+
AG
- Connector used:
2.5mm pitch, 12-pin type, 4.0A nominal current MC0.5/12-G-2.5
connector (made by Phoenix Contact Corp.)
- Applicable plug (bundled):
+
Front-operable spring gauge type FK-MC0,5/12-ST-2,5 plug
AG
+
(made by Phoenix Contact Corp.)
AG
Applicable cable: AWG 28 - 20