System Example 1, Id: 4605169_1103_04 - Viessmann Vitocal 200-S Installation And Service Instructions Manual

Air/water heat pump, split version for heating and cooling operation
Table of Contents

Advertisement

Preparing for installation

System example 1, ID: 4605169_1103_04

Setting system scheme 6
■ Internal unit of the heat pump
type AWB 201.A without instantane-
ous heating water heater or
type AWB-AC 201.A with instantane-
ous heating water heater
■ 1 radiator heating circuit without mixer
A1/HC1
■ 1 underfloor heating circuit with mixer
M2/HC2
Hydraulic installation scheme
WW
37
--2/212.3--
31
30
KW
12
62
--2/F13--
54
52
3
53
50
■ DHW heating
■ External heat source
■ Heating water buffer cylinder
Note
This scheme is a basic example without
shut-off devices or safety equipment.
This does not replace the need for local
engineering.
--2/212.2--
1
29
5
4
6
28
27
55
-2/222.4--51-
14
-2/211.2--14-
2
105
91
-8/145-
71
73
--105/2--
70
90
-105/20--76-
M2
A1
74
--74/20--
96
76
77
--105/52--
61
13
60
8
-8/145-

Advertisement

Table of Contents
loading

Table of Contents