System Example 1, Id: 4605169_1005_01 - Viessmann Vitocal 200-S Installation And Service Instructions For Contractors

Air/water heat pump, split version for heating and cooling operation
Table of Contents

Advertisement

Overview of possible system schemes
Components
Heating circuit
A1
M2
DHW cylinder
Heating water buffer cylinder
External heat source
Solar thermal system
Cooling
A1
M2
Sep. cooling circuit
X
Selected component.
0 The component can be added.

System example 1, ID: 4605169_1005_01

Setting system scheme 6
■ Internal unit of heat pump type AWS
with or without instantaneous heating
water heater
■ 1 radiator heating circuit without mixer
(A1)
■ 1 underfloor heating circuit with mixer
(M2)
■ DHW heating
Only in conjunction with a heating water buffer cylinder.
*1
(cont.)
System scheme (parameter 7000)
0
1
2
X
X
X
X
0
0
*1
*1
0
0
0
0
0
0
0
0
0
■ External heat source
■ Heating water buffer cylinder
Note
This scheme is a basic example without
shut-off valves or safety equipment. This
does not replace the local technical engi-
neering task.
Preparing for installation
3
4
5
X
X
X
X
X
X
X
X
0
0
0
0
0
0
0
0
0
0
0
6
X
X
X
X
0
0
0
0
0
9