Filling And Venting On The Secondary Side; Checking Expansion Vessels And Primary Circuit/Secondary Circuit Pressure; Commissioning The System - Viessmann BW 30 .CS Series Installation And Service Instructions Manual

Table of Contents

Advertisement

Filling and venting on the secondary side

!
Please note
Commissioning when the secondary circuit is
empty causes appliance damage.
Fill and vent the secondary circuit before con-
necting the power supply.
Note
Before filling the system, observe VDI 2035 part 1.
1. Check the Victaulic connections in the heat pump
for tightness. The Victaulic couplings must be form-
locked and fitted together seamlessly.
2. Open any on-site non-return valves if installed.
3. Check the pre-charge pressure of the expansion
vessel.

Checking expansion vessels and primary circuit/secondary circuit pressure

Observe engineering information.
Heat pump technical guide

Commissioning the system

Commissioning is carried out in 3 stages:
1. System configuration
2. Operating mode configuration
3. Adjusting operating parameters
The system is configured with the aid of a commission-
ing assistant. Parameters must be set and the system
controller configured individually according to require-
ments (see the following chapter and service instruc-
tions "Vitotronic SPS heat pump control unit").
Configuration procedure
"Vitotronic SPS" service instructions
Commissioning, inspection, maintenance
4. Fill (flush) and vent the secondary circuit.
!
Please note
Leaking hydraulic connections lead to appli-
ance damage.
Check tightness of the internal and on-site
hydraulic connections.
In the event of leaks, switch OFF the appli-
ance immediately. Drain the secondary cir-
cuit and check the seating of the seals.
Always replace damaged or displaced
seal rings.
5. Check the system pressure and top up with water if
required.
Minimum system pressure: 0.8 bar (80 kPa)
Permiss. operating pressure: 6 bar (0.6 MPa)
Note
The type and extent of parameters depend on the heat
pump type and the system configuration.
Observe the instructions in the separate service
instructions of the Vitotronic SPS heat pump control
unit, otherwise the appliance warranty will be void.
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitocal 300-g pro spsBw 301.cs090Bw 302.cs230

Table of Contents