Watchdog Counter Register; Watchdog State Register; Battery Status Register - Siemens SIMATIC IPC327G Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC327G:
Table of Contents

Advertisement

7.5.5.3

Watchdog counter register

Bit
0 to 7
7.5.5.4

Watchdog state register

Bit
7
6
5
4
3 to 0
7.5.5.5

Battery status register

The status of the CMOS battery is monitored; the status (two-tier) can be read from the
battery status register.
Meaning of the bits
Battery status register (read-only, address 404Dh)
Bit
7
SIMATIC IPC327G
Operating Instructions, 09/2021, A5E51366275-AA
Read/Write
Meaning of the bits
state
Read/Write
Watch Dog Timer I Time-out value. Writing a non-zero value to the regis-
ter causes the counter to load the value into the Watch Dog Counter and
start counting down. The accuracy of watchdog timer I about one cycle
deviation. Non-zero value will be reloaded to the Watch Dog Counter and
the countdown resumes. Reading the register returns the current value in
the Watch Dog Counter but not the Watch Dog Timer Time-out value.
Read/Write
Meaning of the bits
state
Read/Write
Not used for watchdog
Read/Write
Not used for watchdog
Write "1" Only
Trigger Watchdog Timer I event. This bit is self-clearing.
Read/Write
Watchdog Timer I status bit:
Read/Write
Not used for watchdog
6
5
4
3
2
1
0
0
0
1
1
1
00h: Time-out Disable
01h: Time-out occurs after one cycle time, the cycle time is based on
LD8 CRF0, bit[3], by analogy.
0: Watchdog Timer I is running.
1: Watchdog Timer I issues time-out event.
Meaning
0
CMOS battery capacity is still sufficient.
CMOS battery capacity is exhausted (remaining capacity is suffi-
cient for approx. one month)
CMOS battery is empty
Technical specifications
7.5 Hardware descriptions
73