Connecting The Power Supply - Siemens SIMATIC IPC327G Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC327G:
Table of Contents

Advertisement

Installing and connecting the device
3.3 Connecting the device
3.3.3

Connecting the power supply

Note
The equipment is designed for operation with Safety Extra-Low Voltage (SELV) or Protective
Extra-Low Voltage (PELV).
Note
The 24 V DC power supply must be adapted to the input data of the device (see Technical
data (Page 59)).
Note
Terminal blocks do not accommodate more than one individual conductor in a clamping
point.
Requirements
• The function earth is connected.
• You are using the supplied terminal.
• A two-core cable meet the following requirements:
– a copper (Cu) cable cross-section of 0.75 mm
– rated temperature 75 °C
• Tightening torque: 0.56 Nm.
• A slotted screwdriver with approximate 3 mm blade.
28
to 2.5 mm
2
2
Operating Instructions, 09/2021, A5E51366275-AA
SIMATIC IPC327G

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic ipc377g

Table of Contents