Specification
Specification
(cont.)
Type AWT-AC
External unit electrical values
Rated voltage, compressor
Max. operating current, com-
pressor
Starting current, compressor
Starting current, compressor
with stalled armature
MCB/fuse protection
IP rating
Internal unit electrical values
Heat pump control unit/PCB
Rated voltage, control
unit/PCB
MCB/fuse protection, power
supply
Internal fuse
Instantaneous heating water
heater
Rated voltage
Heating output
MCB/fuse protection, power
supply
Electrical power consumption
Fan (max.)
External unit (max.)
Secondary pump (PWM)
Control unit/PCB, external unit
(max.)
Control unit/PCB, internal unit
(max.)
Max. rating, control unit/PCB
Refrigerant circuit
Refrigerant
Refrigerant charge
Global warming potential
(GWP)
CO
equivalent
2
Top-up amount for line lengths
12 m to
30 m
>
Compressor (hermetically
sealed)
Permiss. operating pressure
High pressure side
Low pressure side
124
221.B10
A
A
A
A
IP
kW
W
kW
W
W
W
W
kg
t
g/m
Type
Double rotating pis-
ton
bar
MPa
bar
MPa
221.B13
3/N/PE 400 V/50 Hz
7.85
9.89
10
16
16
X4
1/N/PE 230 V/50 Hz
1 x B16A
6.3 A (slow)/250 V
1/N/PE 230 V/50 Hz
3/N/PE 400 V/50 Hz
8.8
3 x B16A
130
5.0
3 to 50
3 to 50
150
5
1000
1000
R410A
R410A
2.95
2.95
2088
2088
6.20
6.20
60
Double rotating pis-
ton
43
4.3
43
4.3
221.B16
13.09
10
10
16
16
16
16
X4
X4
130
130
6.3
6.3
3 to 50
150
150
5
1000
R410A
4.20
2088
6.20
60
60
Double rotating pis-
ton
43
43
4.3
4.3
43
43
4.3
4.3
5

Advertisement