Certification
6.1.8 Other Approvals
6.1.8
Other Approvals
This device meets the requirements of the following additional standards:
6.2

EMC and Environmental Type Tests

The RUGGEDCOM RS900GF has passed the following Electromagnetic Compatibility
(EMC) and environmental tests.
EMC Type Tests
61000-4-2
61000-4-3
61000-4-4
61000-4-5
61000-4-6
61000-4-8
61000-4-29
30
EN50121-4
Railway applications – Electromagnetic Compatibility – Emission and Immunity
of the Signaling and Telecommunications Apparatus
Test
IEC
ESD
IEC
Radiated RFI
IEC
Burst (Fast Transient)
IEC
Surge
IEC
Induced (Conducted) RFI
IEC
Magnetic Field
IEC
Voltage Dips and Interrupts
Description
Enclosure
Contact
Enclosure Air
Enclosure
Ports
Signal Ports
DC Power
Ports
AC Power
Ports
Earth
Ground Ports
Signal Ports
DC Power
Ports
AC Power
Ports
Signal Ports
DC Power
Ports
AC Power
Ports
Earth
Ground Ports
Enclosure
Ports
DC Power
Ports
Test Levels
± 8 kV
± 15 kV
10 V/m
± 4 kV
± 4 kV
± 4 kV
± 4 kV
± 4 kV Line-to-Earth
± 2 kV Line-to-Line
± 4 kV Line-to-Earth
± 2 kV Line-to-Line
± 4 kV Line-to-Earth
± 2 kV Line-to-Line
10 V
10 V
10 V
10 V
40 A/m Continuous
1000 A/m for 1 s
30% for 0.1 s
100% for 0.02 s
RUGGEDCOM RS900GF
Installation Manual, 01/2021, C79000-G8976-1352-05
Severity
Levels
4
4
3
4
4
4
4
4
4
4
3
3
3