Model
Power source
Cooling capacity
kW *
(Nominal)
kcal/h *
Btu/h *
Power input
kW
Current input A
COP
kW/kW
Temp. range of
Indoor temp.
W.B.
cooling
Outdoor temp. D.B.
Heating capacity
kW *
(Nominal)
kcal/h *
Btu/h *
Power input
kW
Current input A
COP
kW/kW
Temp. range of
Indoor temp.
D.B.
heating
Outdoor temp. W.B.
Indoor unit
Total capacity
connectable
Model/
CITY MULTI
Quantity
Branch box*
Mixed
system
Sound pressure level (SPL)
dB <A>
(measured in anechoic room)
Sound power level (PWL)
dB <A>
(measured in anechoic room)
Refrigerant
Liquid pipe
mm (inch)
piping diameter
Gas pipe
mm (inch)
2
FAN *
Type × Quantity
Airflow rate
K/min
L/s
cfm
Control, Driving mechanism
Motor output
kW
External static press.
Compressor
Type x Quantity
Manufacture
Starting method
Capacity
%
control
Motor output
kW
Case heater
kW
Lubricant
External finish
External dimension H × W × D
mm
inch
Protection
High pressure protection
devices
Inverter circuit (COMP./FAN)
Compressor
Fan motor
Refrigerant
Type × original charge
Control
Net weight
kg (lb)
Heat exchanger
HIC circuit (HIC: Heat Inter-Changer)
Defrosting method
Drawing
External
Wiring
Standard
Document
attachment
Accessory
Optional parts
Remarks
*1 Nominal cooling conditions
Indoor:
27°C D.B./19°C W.B. [81°F D.B/66°F W.B.]
Outdoor:
35°C D.B. [95°F D.B.]
Pipe length:
7.5 m [24-9/16 ft]
Level difference:
0 m [0 ft]
*3 10 to 52:D.B. [50 to 126_F D.B.], when connecting following models: PKFY-P10/15/20/25/32VLM, PFFY-P20/25/32VLEM, PFFY-
P20/25/32VLRM(M), PFFY-P20/25/32VKM, PFFY-P20/25/32VCM, PEFY-P25/32/40VMA3; and M series, S series, and P series type indoor unit.
*4 −15 to 52:D.B. [50 to 126_F D.B.], when using an optional air protect guide [PAC-SH95AG-E]. However, this condition does not apply to the indoor
unit listed in *3.
*5 When connecting 7 indoor units via branch box, connectable CITY MULTI indoor units are 3; connecting 8 indoor units via branch box,
connectable CITY MULTI indoor units are 2.
*6 At least two indoor unit must be connected when using branch box.
Notes: 1. Nominal conditions *
, *
1
2
2. Due to continuing improvement, above specifications may be subject to change without notice.
OCH673D
1
1
1
2
2
2
6
Branch box
CITY MULTI
6
1unit*
Branch box
Branch box
CITY MULTI
6
2unit*
Branch box
*2 Nominal heating conditions
20°C D.B. [68°F D.B.]
7°C DB/6°C W.B. [45°F D.B./43°F W.B.]
7.5 m [24-9/16 ft]
0 m [0 ft]
are subject to ISO 15042.
PUMY-P112YKM4(-BS)
PUMY-P125YKM4(-BS)
3-phase 380-400-415 V, 50 Hz; 3-phase 380 V, 60 Hz
12.5
10,750
42,650
2.79
4.99-4.74-4.57, 4.99
5.84-5.55-5.35, 5.84
4.48
14.0
12,040
47,768
3.04
5.43-5.16-4.98, 5.43
6.31-6.00-5.78, 6.31
4.61
50 to 130% of outdoor unit capacity
P10 - P140 / 9
P15 - P100 / 8
P15 - P140 / 5
P15 - P100 / 5
P15 - P140 / 3 or 2*5
P15 - P100 / 7 or 8*5
49/51
69/71
Scroll hermetic compressor × 1
Mitsubishi Electric Corporation
Cooling 26 to 100
Heating 20 to 100
2.9
Galvanized Steel Sheet Munsell No. 3Y 7.8/1.1
1338 × 1050 × 330(+40)
52-11/16 × 41-11/32 × 13 (+1-9/16)
High pressure Switch
Overcurrent detection, Overheat detection(Heat sink thermistor)
Compressor thermistor, Over current detection
Overheating, Voltage protection, Over current detection
Linear expansion valve
Cross Fin and Copper tube
Reversed refrigerant circuit
Grounded lead wire x1
Joint: CMY-Y62-G-E, Header: CMY-Y64/68-G-E, Branch box: PAC-MK34/54BC
12
PUMY-P140YKM4(-BS)
14.0
12,040
47,768
3.46
7.23-6.87-6.62, 7.23
4.05
15 to 24°C
−5 to 52°C
*3, *4
16.0
13,760
54,592
3.74
7.15-6.79-6.55, 7.15
4.28
15 to 27°C
−20 to 15°C
P10 - P140 / 10
P10 - P140 / 12
P15 - P100 / 8
P15 - P140 / 5
P15 - P100 / 5
P15 - P140 / 3
P15 - P100 / 8
50/52
70/72
9.52 (3/8)
15.88 (5/8)
Propeller Fan × 2
110
1,833
3,884
DC control
0.074+0.074
0
Inverter
Cooling 24 to100
Cooling 21 to 100
Heating 18 to 100
Heating 17 to 100
3.5
0
FV50S(2.3litter)
R410A 4.8 kg
125 (276)
HIC circuit
BK01N339
BH78B814
Installation Manual
Above specification data
is subject to rounding
variation.
15.5
13,330
52,886
4.52
3.43
18.0
15,480
61,416
4.47
4.03
P15 - P100 / 8
P15 - P140 / 5
P15 - P100 / 5
P15 - P140 / 3
P15 - P100 / 8
51/53
71/73
3.9