5.7.2 Reheat mode

5.7.3 Scheduled mode

EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620245-1 – 2020.06
If... is displayed
Only [5.1] Powerful
operation
All items except [5.4] Reheat
setpoint are displayed
All items including [5.4]
Reheat setpoint are
displayed
In reheat mode the DHW tank continuously heats up to the temperature shown on
the home screen (example: 50°C) when the temperature drops below a certain
value.
T t
60°C
50°C
40°C
15°C
00:00
T
DHW tank temperature
t
t
Time
INFORMATION
Risk of space heating capacity shortage for domestic hot water tank without internal
booster heater: In case of frequent domestic hot water operation, frequent and long
space heating/cooling interruption will happen when selecting the following:
Tank > Heat up mode > Reheat only.
INFORMATION
When the DHW tank mode is reheat, the risk for capacity shortage and comfort
problem is significant. In case of frequent reheat operation, space heating/cooling
function is regularly interrupted.
In scheduled mode the DHW tank produces hot water corresponding to a schedule.
The best time to allow the tank to produce hot water is at night, because the space
heating demand is lower.
Example:
T t
60°C
50°C
40°C
15°C
00:00
T
DHW tank temperature
t
t
Time
Then the DHW tank mode =...
Reheat only
Schedule only
Schedule + reheat
1
3
2
4
07:00
14:00
21:00
1
2
4
3
5
07:00
14:00
21:00
5
Operation
|
t
t
User reference guide