Viessmann Vitodens 200 Start-Up/Service Instructions page 66

Wall-mounted, gas-fired condensing boiler
Hide thumbs Also See for Vitodens 200:
Table of Contents

Advertisement

Additional Information
Control Unit for Weather-Responsive Operation
66
(continued)
Scanning temperatures with standard programming unit
The programming unit enables the temperatures of
connected sensors to be scanned as set and actual
values.
Scanning actual temperatures with standard programming unit
1. Select the ID of the respective temperature from the
table.
ID
Meaning of the display Actual temperature in
1* 1
Outside temperature
2
Low loss header
temperature
3
Boiler water temperature 3: 63 ºC
4* 2
Flow temperature
5* 3
DHW cylinder
temperature
7* 4
Room temperature
*1 The display value takes weather conditions into
consideration, such as wind, solar radiation and the
wall temperature of the building.
*2 Only in connection with the extension kit or heating
circuits with mixer.
*3 Only if the sensor is connected or activated.
*4 Only if the programming unit is set into the wall
mounting fixture as room temperature dependent
remote control unit.
2. Press key "?" and turn the rotary selector "G"
anticlockwise or clockwise, until the ID A for the
corresponding temperature is shown on the display.
At the same time, the current temperature B will be
displayed.
Vitodens 200 WB2 Service
ºC (display example)
1:
8 ºC
2: 45 ºC
4: 44 ºC
5: 50 ºC
7: 20 ºC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wb2 6-24cWb2 6-24Wb2 8-32

Table of Contents