Viessmann Vitodens 200 Start-Up/Service Instructions page 65

Wall-mounted, gas-fired condensing boiler
Hide thumbs Also See for Vitodens 200:
Table of Contents

Advertisement

Vitodens 200 WB2 Service
Control Unit for Weather-Responsive Operation
(continued)
Accessing temperature settingswith Comfortrol menu
driven programming unit
The following desired and actual temperature values
can be accessed and shown on the display of the
programming unit:
Outdoor temperature
Boiler water temperature
Supply temperature of the extension kit for the heating
circuit with mixing valve
Room temperature (if programming unit is mounted on
a wall-mount base and used as a remote control).
Open the cover:
Menu option
 HEATING
CIRCUIT A or
HEATING CIRCUIT B or "B"
SYSTEM
 OPERATING STATUS
 CONTINUE
Domestic hot water temperature
Open cover:
Menu option
 DHW
 DHW TANK
 OPERATING STATUS
Depending on the coding, the boiler water temperature
or the outdoor temperature is shown in the first menu on
the display.
Brief scan with standard programming unit
Simultaneously press keys "0" and
"1-7".
Meaning of the display:
A set DHW plan in coding address 03*1
B set heating plan in coding address 04*1
C KM BUS users:
02 with burner control unit
(12) plus Vitocom 100
03 with burner control unit and variable speed heating
circuit pump
(13) plus Vitocom 100
06 with burner control unit and extension kit for one
heating circuit with mixer*2
(16) plus Vitocom 100
07 with burner control unit extension kit for one
heating circuit with mixer*2 and variable speed
heating circuit pump
(17) plus Vitocom 100
*1 For systerns with wall rnounting fixture plug the
prograrnrning unit into the control unit
*2 The systern only recognizes the extension kit if
it is connected via the KM sus
Not if connected via the 2-wire Viessrnann BUS
Additional Information
Button
"A"
"D"
"C" or "B"
"A"
Button
"C"
"A"
"C"
65