Daikin FTK15JEVM Service Manual page 28

Removal procedure 1.5/2.0/2.5/3.2/3.5/4.6 kw class 9000/12000 btu/h class
Table of Contents

Advertisement

Removal of Fan Rotor / Fan Motor (Pattern 1)
Step
5
Unfasten the 2 hooks of
the motor cover.
6
Pull out the fan motor
from the fan rotor to
remove.
26
Procedure
Hook
Motor cover
Magnet
(R8051)
The magnet of the fan motor
is united with the fan rotor.
Fan motor
Coil
Be careful not to attract
metal waste to the magnet.
Keep away from the
materials that can be
affected by magnetic force
also.
(R8052)
(R8053)
Si041051