Daikin FTK15JEVM Service Manual page 12

Removal procedure 1.5/2.0/2.5/3.2/3.5/4.6 kw class 9000/12000 btu/h class
Table of Contents

Advertisement

Removal of Electrical Box / Vertical Blades (Pattern 1)
Step
2
Disconnect the
connector for the fan
motor [S200].
Release the fan motor
harnesses from the
hook.
Remove the screw of
3
the electrical box.
Slide the electrical box
4
to the right first and
detach the horizontal
blade from the electrical
box.
Pull the electrical box.
5
10
Procedure
[S200]
Bottom frame
Hook
Points
(R15844)
(R12048)
(R15845)
There is a hook on the
bottom frame. When
reassembling, fit the rear
side of the electrical box to
the hook.
(R11657)
Removal Procedure
Si041051
Hook
(R14602)