16.
If it is necessary to replace the display hinges, remove the three Phillips M2.5x11.0 screws that secure
each hinge (1), and then remove the hinges from the display enclosure (2).
Display hinges (for touch displays) are available in the Hinge Kit using spare part number L15538-001.
Display hinges (for non-touch displays) are available using spare part number L15539-001.
17.
If it is necessary to replace the display cable, lift the cable from the routing path in the display enclosure.
The display cable is available in the Cable Kit, using spare part number L14370-001.
18.
If it is necessary to replace the camera/ambient light sensor cable: