If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized
Field Service Facility for technical troubleshooting assistance before you proceed.
Observe all Safety Guidelines detailed throughout this manual
ON BOARD LED'S FOR THE STT SWITCH PC BOARD
STT SWITCH PC BOARD
LED2
LED3
(STATUS)
(+15V)
ON
Normal Condition – STT
ON
ON
ON
Normal Condition – STT
Note: During normal STT
detectable as a slight dimming.
OFF
Status Failure (only when triggered). Should be accompanied by Error 99 on the
ON
external STT Module Status LED. Most likely caused by weld cable miscon-
nection (reverse polarity).
OFF
ON/OFF
Status Failure (constantly). Should be accompanied by Error 99 on the external
STT Module Status LED. Most likely caused by the on board power supply
under-voltage lockout. Verify input voltage to the STT Switch board.
B1
B5
INDICATION
®
Switch is ON.
®
Switch has been commanded OFF.
®
operation the OFF state of the LED may only be