Fisher & Paykel OR48DDPWGX1 Installation Instructions Manual page 19

Fisher & paykel or48ddpwgx1: install guide
Hide thumbs Also See for OR48DDPWGX1:
Table of Contents

Advertisement

Available languages

Available languages

INJECTORS TABLE
BURNERS
Rapid (R)
Triple ring (TC)
Inner crown
Dual (D)
Outer crowns
(*) Power calculated only with inner crown operating
(#) Power calculated with inner and outer crowns operating
OPERATIONS TO BE PERFORMED WHEN SUBSTITUTING
THE INJECTORS
✓ Remove the gratings and the burner covers;
✓ Using a wrench substitute the nozzle injectors "J" (figs. 2.10a - 2.10b - 2.10c) with
those most suitable for the kind of gas for which it is to be used.
The burner are constructed in such a way so as not to require the regulation of
the primary air.
Rapid
burner
Fig. 2.10a
DUAL
burner
J
Injectors for
outer crowns
Fig. 2.10c
NOMINAL POWER
BTU/hr
10000
12000
2800
for NATURAL GAS (*)
3500
for LP/PROPANE GAS (*)
16000
for NATURAL GAS (#)
15000
for LP/PROPANE GAS (#)
Triple ring
burner
J
Fig. 2.10b
REDUCED POWER
BTU/hr
2000
5000
1000 (*)
6500
for NATURAL GAS (#)
4500
for LP/PROPANE GAS (#)
J
Injector for inner crown
LP/PROPANE
11" W.C.P.
Ø injector
By-pass
[1/100 mm]
[1/100 mm]
94
42
102
65
55
27
(no. 1 central)
72
60
(no. 2 outer)
J
2
NATURAL GAS
4" W.C.P.
Ø injector
By-pass
[1/100 mm]
[1/100 mm]
155
adjustable
170
adjustable
80
adjustable
(no. 1 central)
130
adjustable
(no. 2 outer)
19