Toshiba MMK-AP0157HP-E Service Manual page 97

Mult type
Table of Contents

Advertisement

SMMS High-Wall Type
Adjustment of air direction
1. Using the remote controller switch, change
the up/down air direction by moving the
horizontal louver.
2. Adjust the right/left air direction by bending
the vertical grille inside of the air outlet port
with hands.
REQUIREMENT
Do not touch the horizontal louver directly with
hands; otherwise a trouble may be caused.
For handling of the horizontal louver, refer to
"Owner's Manual" attached to the outdoor unit.
Group control
In a group control, a remote controller can control
up to maximum 8 units.
• The wired remote controller only can control a
group control. The wireless remote controller is
unavailable for this control.
• For cabling procedure and cables of the
individual line (Identical refrigerant line) system,
refer to "Electric work" in this Manual.
• Cabling between indoor units in a group is
performed in the following procedure.
Connect the indoor units by connecting the
remote controller inter-unit cables from the
remote controller terminal blocks (A, B) of the
indoor unit connected with a remote controller to
the remote controller terminal blocks (A, B) of the
other indoor unit. (Non-polarity)
• For address setup, refer to the Installation
Manual attached to the outdoor unit.
NOTE
Net work adapter (Model TCB-PCNT20E) can not
connect to this High Wall type air conditioner.
1111058602_EN.indd 29
- 97 -
FILE NO. SVM-18070
Installation Manual
Installation Manual
11/24/16 11:41 AM
11110586

Advertisement

Table of Contents
loading

Table of Contents