Adjusting The Blower Speed; Instruction Card; Normal Operating Sounds; Normal Operating Odors - Travis Industries 864 HH Owner's Manual

Operation maintenance
Hide thumbs Also See for 864 HH:
Table of Contents

Advertisement

Adjusting the Blower Speed

The blower helps transfer heat from
the heater into the room. It will not
turn on until the heater is up to
temperature (approximately 10
minutes after starting). See the
illustration below for instructions on
adjusting the blower speed.

Instruction Card

An instruction card is attached to the appliance for future reference. A copy is shown below.
FOR YOUR SAFETY READ BEFORE LIGHTING
A. This appliance is equipped with an ignition device which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the
knob will not push in or turn by hand, don't try to repair it, call a qualified service
technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified
service technician to inspect the appliance and to replace any part of the control
system and any gas control which has been under water.
E. Do not block any control compartments, screens or circulating air passageways.
These areas provide air necessary for safe operation.
DO NOT REMOVE THIS INSTRUCTION PLATE
WARNING:

Normal Operating Sounds

Blower Snap Disk
This part can produce a
clicking sound as it turns
the blower on and off.
Gas Control Valve
As the gas control valve is turned
on and off you will hear a dull
clicking sound. This is the valve

Normal Operating Odors

This appliance has several areas that reach high temperatures. Dust or other particles on these
areas may burn and create an odor. This is normal during start-up. You may notice the smell is
more acute if the appliance was left idle for a long period.
© Travis Industries
Operation
1. STOP! Read the safety information to the left and at the bottom
of this label before proceeding.
2. Set the thermostat to lowest
setting (if applicable).
3. Turn off the blower (room air fan)
on the appliance (if applicable).
4. Push the gas control knob in
slightly and turn it clockwise to
the "OFF" position.
NOTE: The knob will not turn
from "ON" to "OFF" unless the
knob is depressed slightly. Do
not force.
5. Wait five (5) minutes to clear out
any gas. Then smell for gas,
including near the floor. If you
smell gas, STOP! Follow "B" in
the safety information to the left
on this label. If you don't smell
gas, go to the next step.
6. Turn gas control knob
counterclockwise to the "PILOT" position.
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE. WHEN LIGHTING OR RE-LIGHTING THE PILOT, THE DOOR MUST BE OPEN OR THE GLASS REMOVED. AFTER THE PILOT
IS LIT, CLOSE AND LATCH THE DOOR OR REPLACE THE GLASS BEFORE LIGHTING THE BURNER.
OFF
HIGH
Turn the dial all the
The high position is all the
way counter-clockwise
way counter-clockwise,
until it clicks off.
without clicking off.
LIGHTING INSTRUCTIONS
7A
7B
4
7. A) Press the knob in and hold.
B) Immediately press the igniter
button repeatedly until the pilot is
lit. WARNING: If the pilot does
6
not light after 15 seconds, release
the knob and call your dealer
for service.
C) Keep the gas control knob
depressed for 30 seconds once
the pilot is lit.
8. Release the gas control knob. If the pilot goes out, repeat step 7.
• If the knob does not pop up when released, stop and
immediately call your service technician or gas supplier.
The appliance may creak with change of
temperature -- THIS IS NORMAL.
Blowers
This heater has optional blowers to push
heated air into the room. You will hear the
sound of air movement that increases as
the speed is increased.
Extinction Pops
It is not unusual, especially on Propane
(LP) appliances, to experience a "pop"
when the burner is shut off.
Pilot Flame
The pilot flame, which remains on,
makes a very slight "whisper" sound.
4080218
LOW
Turn the dial all the
way clockwise.
TO TURN OFF GAS TO APPLIANCE
1. Set the thermostat to lowest setting
3
(if applicable).
2. Turn off the blower (room air fan) on the
appliance.
3. Push the gas control knob in slightly and
turn it clockwise to the "OFF" position.
NOTE: The knob will not turn from "ON" to
"OFF" unless the knob is depressed slightly.
Do not force.
If the pilot will not stay lit after several tries, turn the gas control knob to
"OFF" and call your service technician or gas supplier.
7C
9. Turn the gas control knob counterclockwise to "ON".
10. Turn on the blower (room air
fan) on the appliance.
9
11. Set the thermostat to desired
setting (if applicable) or use
the ON/OFF rocker switch or
remote control to operate the
main burner.
100-01181_003
9
0330

Advertisement

Table of Contents
loading

This manual is also suitable for:

864 hh fireplace

Table of Contents