Chapter 3: Advanced Programming
This section covers Menus and Submenus not covered as part of Basic Programming: Manual Watering, Stop Menu, and Diagnostics and
Alarms.
I. Manual Watering
•
Manual
•
Start / Stop Program
Manual
(2 Fields to set: Station number and duration of manual run)
It is possible to manually operate up to six stations at one time. As shown in Step 3, use the Control Knob to select the station to run. Then
press ENTER or the Control Knob. The default run time is 30 minutes. It is possible to adjust the run time manually at any time during the
run time.
Activating a station requires power. Exceeding the maximum allowable output current when turning on multiple stations will one, cause the
controller to automatically turn off the station that caused the condition, and two, flag the station so that it will not run again. This is a safety
feature that prevents an over-current condition from exceeding the output capacity of the satellite. If the station is checked and found to be
electrically safe, remove the disable flag through the Over Currents (Alarms) menu item.
1
2
3
ENTER
- OR -
ENTER
- OR -
25