Advanced Irrigation Program Setting:
Advance Irrigation Program example: Create program 2 with stations 6–10 for 15 minutes each with no percent
adjustment. Set the start time 01 at 5:45 am every Monday, Wednesday and Friday only. Set the maximum
simultaneous active station to 5.
1. Press the Scheduled Watering Key
Input Dial
program 02.
2. Press the Right Arrow Key
unless weather or other condition suggest that less or more irrigation is needed. Use the Input Dial
to adjust the setting. For this example, no adjustment is needed.
3. Press the Down Arrow
operation. Select from None, Today, 02–30 days or Permanent. For this example, select None.
4. Press the Down Arrow
adjust the setting. For this example, set the Type to Advanced.
5. Press the Down Arrow
select the program activation interval from 01–30 days. Select 01 for everyday, 02 for every other day, 03 for
every third day and so on. The example does not call for a set interval. Leave the Days: setting to
SMTWTFS.
6. Press the Down Arrow
from any of the preset intervals (All, Alternate days, Weekdays only, Weekends only, None or User set). To
create your own program activation interval, select Set:. Use the Right Arrow Key
the week you want to irrigate and use the Input Dial
selection. For this example, activate M (Monday), W (Wednesday) and F (Friday) only. MWF of the 1st and 2nd
week should have an X mark under while the rest are blank.
7. Press the Down Arrow
start time number. Each program can have a maximum of 24 start times. Use the Input Dial
choose the start time being created or modified. Press the Right Arrow Key
field. Use the Input Dial
additional start times. For this example, set start time 01 to 05:45am.
8. Press the Down Arrow
activate Syringe by entering a syringe runtime. If activated, the program will run all stations for the duration
specified, regardless of the individual station runtimes. Leave the syringe runtime at 00 min.
9. Press the Down Arrow
enter the amount of repeats the program will execute after activation. Leave the Repeat value to 0.
10. Press the Down Arrow
enter soak time. The soak time will indicate the delay before the program will repeat or cycle again. Leave the
soak time to – – : – – : – – for no soak delay.
11. Press the Down Arrow
select the correct value of the first station being irrigated. For this example, select station 06.
12. Press the Right Arrow
the range. If irrigating only one station, this value should be the same as the first value. For this example,
select station 10.
18
. The cursor is initially located at the program selection field. Use the
to select the program (P01–P64) you want to create or modify. For this example, select
to advance to the Percent Adjust field. Normally this setting will be 100%
to advance the cursor to the Hold: field. Use this option to suspend program
to advance the cursor to the Type: field. Use the Input Dial
to advance the cursor to the Days: field. Use the Input Dial
to advance the cursor to the Set: field. Use the Input Dial
to advance the cursor to the Start: field. The first entry field will indicate the
to select the start time in hours and minutes ( HH:MM). Repeat Step 7 for
to advance the cursor to the Syringe: field. Use the Input Dial
to advance the cursor to the Repeats: field. Use the Input Dial
to advance the cursor to the Soak: field. Use the Input Dial
to advance the cursor to the Sta#: field. Use the Input Dial
to advance the cursor to the next value. This value will indicate the last station of
to select the day of
to activate (X) or deactivate (blank) the
to advance to the time entry
to
to
to select
to
to
to
to
to

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents