PV Series
Venting Specifications for:
RG2PV50H
LG2PV50H
8
8
Vent Tables
3" Diameter (7.6 cm) Vent Connector Lengths
# of
Terminating
Elbows
Through the Wall
Through the Wall
Through the Wall
Through the Wall
Through the Roof
Through the Roof
Through the Roof
Through the Roof
4" Diameter (10.2 cm) Vent Connector Lengths
# of
Terminating
Elbows
Through the Wall
Through the Wall
Through the Wall
Through the Wall
Through the Wall
Through the Roof
Through the Roof
Through the Roof
Through the Roof
Through the Roof
Maximum Straight
Length ft. (m)
55 (16.8)
1
50 (15.2)
2
45 (13.7)
3
40 (12.2)
4
60 (18.3)
0
55 (16.8)
1
50 (15.2)
2
45 (13.7)
3
Maximum Straight
Length ft. (m)
175 (53.3)
1
170 (51.8)
2
165 (50.3)
3
160 (48.8)
4
155 (47.2)
5
180 (54.9)
0
175 (53.3)
1
170 (51.8)
2
165 (50.3)
3
160 (48.8)
4
Specifications
Minimum Straight
Length ft. (m)
2 (.6)
2 (.6)
2 (.6)
2 (.6)
7 (2.1)
7 (2.1)
7 (2.1)
7 (2.1)
Minimum Straight
Length ft. (m)
10 (3.1)
10 (3.1)
10 (3.1)
10 (3.1)
10 (3.1)
15 (4.6)
15 (4.6)
15 (4.6)
15 (4.6)
15 (4.6)