Trane Sintesis Balance CMAF Installation Operation & Maintenance page 22

Air-to-water multi-pipe scroll unit
Table of Contents

Advertisement

General Data
Table 4 - General data CMAF 080-130 High Efficiency (Continued)
Unit size
Combinations with Hot water Package
Without chilled water pump and with hot water
pump single or dual package without buffer
FWD
tank (digit 24=X, digit 50=X, digit 59≠X)
Power supply
With chilled water single pump and with hot
Capacities
water pump single or dual package without
Cooling capacity on water (1)
buffer tank (digit 24=1/3, digit 50=X,
Heating capacity on water (2)
digit 59≠X)
Fan motor
With chilled water dual pump and with hot
Fan power input (3)
water pump single or dual package without
Current amps (3)
buffer tank (digit 24=2/4, digit 50=X,
Start-up amps
digit 59≠X)
Air flow
With chilled water single pump and with hot
minimum
water pump single or dual package without
nominal
buffer tank (digit 24=1/3, digit 50≠X,
maximum
digit 59≠X)
Main coil
With chilled water dual pump and with hot
Water entering/leaving connections
water pump single or dual package with buffer
tank (digit 24=2/4, digit 50≠X, digit 59≠X)
Electric heater (accessory for blower only)
Dimensions and weight (basic model only)
Electric power supply
Length
Heating capacity
Width
Hot water coil (accessory for blower only)
Height
Heating capacity (4)
Pump Package Option - (Additional length)
G2 filter (filter box accessory)
Weights
Quantity
Operating Weight
Dimensions ( LxWxth)
Additional Shipping Weight
G4 filter (filter box accessory)
Additional Weight of options
Quantity
Chilled water pump
Dimensions ( LxWxth)
Single pump - Standard head pressure
Condensate pump (accessory)
Single pump - High head pressure
Water flow - lift height
Twin pump - Standard head pressure
Not available for FWD30 and FWD45
Twin pump - High head pressure
Sound level (L/M/H speed)
Hot water pump
Sound pressure level (5)
Single pump - Standard head pressure
Sound power level (5)
Single pump - High head pressure
Unit dimensions
Double pump - Standard head pressure
Width x Depth
Double pump - High head pressure
Height
Extra Low Noise (XLN) Option
Shipped unit dimensions
Optional Pump VFD
Width x Depth
Optional Chilled Water Buffer tank
Height
Oil and Refrigerant Charge (R410A)
Weight
Total Refrigerant charge Circuit 1/2 (6)
Colour
Refrigerant Charge per cooling kW (6)
Recommended fuse size
POE Oil Type
Unit alone (aM/gI)
Oil charge Circuit 1 / 2 (6)
Unit with electric heater (gI)
(1) Indicative performance at chilled water exchanger water temperature : 12˚C / 7˚C and air temperature 35˚C for cooling only mode & hot water
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
exchanger temperature: 40˚C / 45˚C and air temperature 7˚C (6˚C) for heating only mode for- detailed performances, on a given unit, consult Order
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
Write Up.
(3) At high speed with nominal air flow.
(2) Under 400V/3/50Hz.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(3) Rated Condition without Pump Package.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
(4) Electrical & system data are indicative and subject to change without notice. Please refer to unit nameplate data.
Heat exchanger operating limits:
(5) Hot water exchanger temperature 40˚C / 50 ˚C and air temperature 7˚C (6˚C) for heating only mode.
FWD:
(6) Refrigerant and oil charges are indicative. Refer to unit nameplate for real charges.
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars
Accessories - Hot water coil:
*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
4
22
Technical Data
080
kW
1.16
08
(V/Ph/Hz)
kW
1.80
(kW)
5,2
(kW)
6,3
(type)
(kW)
0,23
kW
1.86
(A)
1,1
(A)
3,2
(m
/h)
490
3
kW
2.68
(m
/h)
820
3
(m
/h)
980
3
(type)
kW
2.80
(Dia)
3/4"
(V/Ph/Hz)
230/1/50
mm
4520
(kW)
2/4
mm
2200
mm
2530
(kW)
6,3
mm
555
2
kg
2737
(mm)
386x221x8
kg
12
-
(mm)
-
kg
254
(type)
kg
301
(l/h - mm)
kg
343
kg
425
(dB(A))
36/40/43
kg
145
(dB(A))
46/50/53
kg
187
kg
225
(mm)
890 x 600
kg
307
(mm)
250
kg
115
kg
85
(mm)
933 x 644
kg
253
(mm)
260
(kg)
32
kg
44/45
kg/kW
0.32
(A)
8/16
l
15.3 / 15.3
(A)
16 (2kW),25 (4kW)
090
100
1.22
1.22
12
20
230/1/50
1.86
1.86
8,3
15
11,9
18,9
2 x direct drive centrifugal
0,46
0,65
1.92
1.92
2,2
3,1
5,5
9,3
980
1400
2.74
2.74
1650
2300
1970
2600
ISO R7 rotating female
2.80
2.90
3/4"
1 1/2"
230/1/50 or 400/3/50
400/3/50
4520
4520
8
10
2200
2200
2530
2530
12
17,4
555
555
2
2
2869
2970
486x271x8
586x321x8
12
12
2
2
486x264x48
586x314x48
254
254
Centrifugal
301
301
24 - 500
343
343
425
425
38/41/44
46/50/53
145
145
48/51/54
56/60/63
187
187
225
225
1090 x 710
1290 x 820
307
307
300
350
115
115
85
85
1133 x 754
1333 x 864
253
253
310
360
46
61
45/45
44/45
galvanised steel
0.29
0.26
OIL058E / OIL057E
8/16
8/16
15.3 / 15.3
15.4 / 15.4
40 (230V),3*16 (400V)
3*20
110
130
1.32
1.42
30
45
1.96
2.06
18,8
30,1
20,9
38,2
1,04
1,51
2.02
2.12
4,7
5,5
14,1
16,5
1800
2700
2.84
2.94
3000
4500
3600
5400
3.00
3.75
1 1/2"
1 1/2"
400/3/50
400/3/50
4520
4520
12
12
2200
2200
2530
2530
22,4
34,5
555
555
2
2
3102
3209
586*421*8
586*621*8
12
12
2
2
586*414*48
586*614*48
264
264
301
301
363
363
425
425
47/52/57
47/52/58
145
145
57/62/67
57/62/68
187
187
225
225
1290 x 970
1290 x 1090
307
307
450
650
115
115
85
85
1333 x 1008
1333*1133
253
253
460
660
76
118
44/45
45/46
0.23
0.21
8/25
8/25
15.4 / 15.4
15.4 / 15.4
3*25
3*25
CG-SVX051A-GB
UNT-PRC002-GB

Hide quick links:

Advertisement

Table of Contents
loading