MAINTENANCE AND TROUBLESHOOTING

Inspect and properly tighten all parts of the elliptical
trainer regularly. Replace any worn parts immediately.
The elliptical trainer can be cleaned with a soft cloth
and a small amount of mild detergent. Do not use
abrasives or solvents. To prevent damage to the
console, keep liquids away from the console and keep
the console out of direct sunlight.
When storing the elliptical trainer, remove the batter-
ies from the console. Keep the elliptical trainer in a
clean, dry location, away from moisture and dust.
CONSOLE TROUBLESHOOTING
If the console does not function properly, replace the
batteries (see assembly step 3 on page 6).
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted. To adjust the reed
switch, first see assembly step 9 on page 8 and
remove the Pedals (13, 14). Next, see step 8 on page
8 and remove the Pedal Arms (11, 12).
15
4
3
71
72
51
71
64
Next, remove the four Screws (51, 72) from the right
Pedal Disc (15), and slide the Pedal Disc off. Remove
all Screws (71, 64) from the Right Side Shield (4), and
remove the Right Side Shield. Remove all Screws
(52) from the Left Side Shield (3) and remove the Left
Side Shield.
64
52
12
64
64
14
51
52
19
Next, locate
the Reed
Switch (53).
Loosen, but
do not
remove, the
indicated
Screw (52).
Slide the
Reed Switch
slightly toward
or away from
the Magnet (58) on the flywheel. Retighten the Screw.
Turn the left Pedal Disc (15) for a moment. Repeat
until the console displays correct feedback.
When the Reed Switch (53) is correctly adjusted, reat-
tach the Side Shields (3, 4), the right Pedal Disc (15),
the Pedal Arms (11, 12), and the Pedals (13, 14).
HOW TO ADJUST THE DRIVE BELT
If you can feel
the pedals slip
whilst you are
pedaling, even
when the resis-
tance is adjust-
ed to the maxi-
26
mum level, the
Drive Belt (19)
may need to
62
be adjusted. To
adjust the
Drive Belt, you
must remove both side shields. See the instructions at
the left and remove the side shields.
Next, loosen the M8 x 22mm Flat Head Screw (26)
and turn the M10 x 60mm Screw (62) until the Drive
Belt (19) is tight. Once the Drive Belt is tight, tighten
the Flat Head Screw. Reattach the side shields.