Wiring Diagrams; Warranty; Replacement Parts; Product Reference Information - Lennox Hearth Products Signature Montebello Series Homeowner's Care And Operation Instructions Manual

Direct vent
Table of Contents

Advertisement

WIRING DIAGRAMS

Wiring diagrams are provided here for refer-
ence purposes only. This information is also
provided on schematics attached directly to
the appliance on a pullout panel located within
the control compartment.
CAUTION: LABEL ALL WIRES PRIOR TO DIS-
CONNECTION WHEN SERVICING CONTROLS.
WIRING ERRORS CAN CAUSE IMPROPER AND
DANGEROUS APPLIANCE OPERATION.
Millivolt Wiring Diagram
If any of the original wire as supplied must be replaced,
it must be replaced with Type AWM 105°C – 18 GA. wire.
Thermopile
APPLIANCE-MOUNTED ON/OFF SWITCH
*OR OPTIONAL WALL-MOUNTED ON/OFF SWITCH OR
OPTIONAL REMOTE CONTROL RECEIVER OR THERMOSTAT
*Turn the appliance-mounted ON/OFF burner control switch
to the OFF position if an optional
control switch is installed.
Schematic Representation Only

WARRANTY

Your gas appliance is covered by a limited
twenty year warranty. You will find a copy of
the warranty accompanying this manual.
Please read the warranty to be familiar with its
coverage.
Retain this manual. File it with your other
documents for future reference.

PRODUCT REFERENCE INFORMATION

We recommend that you record the following important information about your fireplace. Please
contact your Lennox dealer for any questions or concerns. For the number of your nearest Lennox
dealer, please call 800-731-8101
Your Fireplace's Model Number _______________________________________
Your Fireplace's Serial Number ________________________________________
The Date On Which Your Fireplace Was Installed __________________________
The Type of Gas Your Fireplace Uses ___________________________________
Your Dealer's Name _________________________________________________
10
PILOT BURNER
IGNITER-SENSOR
ASSEMBLY
CONNECTOR
Field Wired
Factory Wired

REPLACEMENT PARTS

A complete parts list is found at the end of this
manual. Use only parts supplied from the
manufacturer.
Normally, all parts should be ordered through
your Lennox distributor or dealer. Parts will be
shipped at prevailing prices at time of order.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
WHITE
EV2
EV1
GAS VALVE
BLUE (20)
GROUND
BLACK (20)
GREEN LED
ELECTRONIC IGNITION
CONTROL BOARD
ELECTRONIC
OPTIONAL
WIRING DIAGRAM
ACCESSORY SW
GND
ITEM 45
WIRE #2
W
BLK/RED
JUNCTION BOX
BLK
W
WHITE (6)
APPLIANCE MOUNTED
ON/OFF SWITCH
BLACK (16)
ITEM 45 WIRE #3
*WALL MOUNTED ON/OFF SWITCH (OPTIONAL) OR
REMOTE CONTROL RECEIVER OR OPTIONAL THERMOSTAT
*Turn The Appliance-Mounted ON/OFF Burner Control Switch
To The OFF Position If An Optional Control Switch Is Installed
FIELD WIRED
When ordering repair parts, always give the
following information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
If you encounter any problems or have any
questions concerning the installation or appli-
cation of this system, please contact your
distributor, or Lennox directly:
LENNOX HEARTH PRODUCTS
1110 West Taft Avenue
Orange, CA 92865
120 VAC
BLK
W
GND
TRANSF
120 V.
24 V.
FACTORY WIRED

Advertisement