Operation of millivolt and electronic gas con-
trol systems are different. Before lighting and
operating your appliance determine if you
have a millivolt or electronic appliance.
Refer to Figure 1 for access to the gas control
valve. Millivolt appliances will be fitted with
the gas control valve shown in Figure 2 .
Appliances with electronic systems will be
fitted with the electronic valve shown in
Figure 3 . Familiarize yourself with the gas
control valve that your appliance uses.
Millivolt Appliances -
To light millivolt appliances refer to the de-
tailed lighting instructions found on page 11 .
Millivolt appliance lighting instructions may
also be found on the pull out lighting instruc-
tion labels attached to the gas control valve.
Millivolt appliances are fitted with an ON/OFF
Rocker Switch for appliance ON/OFF control.
See Figure 1 for its location. Once the pilot is
lighted, the ON/OFF rocker switch will control
the appliance ON/OFF operation. To operate:
Toggle the switch between its ON and OFF
positions.
If your millivolt appliance is equipped with an
optional remote wall switch or remote control
kit and the pilot is lit, the appliance main
burner may be turned on and off with the wall
switch or remote control.
Electronic Appliances -
To light electronic appliances refer to the de-
tailed lighting instructions found on page 12
of these instructions respectively. Electronic
appliance lighting instructions may also be
found on the pull out lighting instruction
labels attached to the gas control valve.
Variable Flame Height Adjustment
Manifold Pressure Port
SIT Millivolt Gas Valve
Figure 2
4
HI
LO
SIT Electronic Gas Valve
Figure 3
Electronic appliances are fitted with an ON/
OFF Rocker Switch for appliance ON/OFF con-
trol. See Figure 1 for its location.
Once the pilot is lighted, the ON/OFF rocker
switch will control the appliance ON/OFF op-
eration. To operate: Toggle the switch be-
tween its ON and OFF positions.
If your electronic appliance is equipped with an
optional remote wall switch or remote control
kit the appliance main burner may be turned on
and off with the wall switch or remote control.
Variable Flame Height Adjustment
All appliances are equipped with a variable gas
control valve. Flame height for these models
may be adjusted through a range between
fixed low and high settings, alternately, while
the appliance is in operation.
Use the extension knob ( refer to Figure 1 ), to
adjust the flame height as desired by sliding
the knob over the variable flame adjustment
knob located on the front of the valve ( refer to
Figure 2 ). Replace the extension knob back
to the hanger after the adjustment.
Inlet Pressure Port
Main Gas
Control Knob
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Glass Cleaning

It will be necessary to clean the glass periodi-
cally. During start-up it is normal for conden-
sation to form on the inside of the glass. This
can cause lint, dust and other airborne par-
ticles to cling to the glass surface. Also initial
paint curing may deposit a slight film on the
glass. It is therefore recommended that the
glass be cleaned two or three times with a non-
ammonia household cleaner and warm water
(a gas fireplace glass cleaner is recommended).
After that the glass should be cleaned two or
three times during each heating season, de-
pending on the circumstances present.
Note: Clean glass after first two weeks of
operation.
WARNING: DO NOT USE ABRASIVE
CLEANERS. NEVER CLEAN THE GLASS
WHEN IT IS HOT.
CAUTION: DO NOT ATTEMPT TO TOUCH THE
FRONT ENCLOSURE GLASS WITH YOUR
HANDS WHILE THE FIREPLACE IS IN USE.

Maintenance

The appliance and venting system should be
thoroughly inspected before initial use and at
least annually by a qualified service techni-
cian. However, more frequent periodic in-
spections and cleanings should be performed
by the homeowner. Homeowner must contact
a qualified service technician at once if any
abnormal condition is observed.
Keep side control compartment clean by vacu-
uming or brushing at least twice a year. More
frequent cleaning may be required due to
excessive lint from carpeting, bedding materi-
als, etc. It is important that control compart-
ments, burners and circulating air passage-
ways of the appliance be kept clean.
Always turn off gas to the pilot (millivolt appli-
ances) before cleaning. Before re-lighting, re-
fer to the lighting instructions in this manual.
Instructions are also found on pull-out light-
ing instruction labels attached to the gas valve.
Always keep the appliance area clear and free
from combustible materials, gasoline and other
flammable liquids.
Remember, Millivolt appliances have a con-
tinuous burning pilot flame. Exercise caution
when using products with combustible vapors.