Replacement Parts; Product Reference Information; Wiring Diagrams - Lennox Hearth Products MLDVTCD-35NM Care And Operation Instructions Manual

Merit series
Hide thumbs Also See for MLDVTCD-35NM:
Table of Contents

Advertisement

LENNOX HEARTH PRODUCTS • MERIT
ORDERING REPLACEMENT
PARTS
A complete parts list is found at the end of
this manual. Use only parts supplied from the
manufacturer.
With proper care and maintenance, your appli-
ance will provide many years of enjoyment. If
you should experience any problem, first refer
to the troubleshooting guide in this manual.
If the problem persists, contact your Lennox
Hearth Products dealer or distributor.
Order parts through your Lennox Hearth Prod-
ucts distributor or dealer. Parts will be shipped
at prevailing prices at time of order.
When ordering parts, provide the following
information:
1. Appliance model number.
2. Appliance serial number.
3. Part number.
4. Part description.
5. Quantity required.
6. Appliance installation date.

WIRING DIAGRAMS

Wiring diagrams are provided here for reference
purposes only. This information is also provided
on schematics attached directly to the appliance
on a pullout panel located within the control
compartment.
WIRING DIAGRAM MILLIVOLT GAS VALVES
THERMOPILE
OPTIONAL APPLIANCE-
MOUNTED ON/OFF
SWITCH
TP-TH
BK/W(1)
BK/W(1)
WALL-MOUNTED ON/OFF SWITCH (OPTIONAL)
THERMOSTAT (OPTIONAL)
WALL MOUNTED CONFIGURATION FOR FAN SWITCH (OPTIONAL)
FAN
(OPTIONAL)
Figure 11
16
SERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • CARE AND OPERATION
®
If you encounter any problems or have any
questions concerning the installation or ap-
plication of this system, please contact your
dealer or distributor.
PRODUCT REFERENCE
INFORMATION
We recommend that you record the important
reference information about your fireplace in
the space provided below.
Model Number ________________________________________________________
Serial Number ________________________________________________________
Date Installed _________________________________________________________
Gas Type Used ________________________________________________________
Dealer Name _________________________________________________________
CAUTION: LABEL ALL WIRES
PRIOR TO DISCONNECTION WHEN
SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER
AND DANGEROUS APPLIANCE
OPERATION.
120 VAC
BK W GR
TP
TH
GAS VALVE
BK
R
W
GR
OR THERMOSTAT
JUNCTION BOX
Figure 12
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

PRODUCT REFERENCE INFORMATION

INTERMITTENT ELECTRONIC WIRING DIAGRAM
OPTIONAL BLOWER
SWITCH
JUNCTION BOX
TRANSFORMER 3V
FAN
(OPTIONAL)
TO WALL
SWITCH, FRS
BROWN
Please call Lennox Hearth Products for the
phone number of your nearest LHP dealer,
who will answer your questions or address
your concerns.
LENNOX HEARTH PRODUCTS
1508 Elm Hill Pike, Suite 108
Nashville, TN 37210
Visit us at www.Lennox.com
1-800-9-LENNOX
ATTENTION : AU MOMENT DE
L'ENTRETIEN DES COMMANDES,
ÉTIQUETEZ TOUS LES FILS AVANT
DE LES DÉBRANCHER. DES
ERREURS DE CÁBLAGE PEU-VENT
ENTRAÎNER UN FONCTIONNEMENT
INADÉQUAT ET DANGEREUX.
IGNITER MODULE
3V
BLACK (IGNITER)
BLACK (SENSOR)
BLACK
ORANGE (THTP)
BATTERY BACK-UP
BLACK (TP)
RED
GREEN (TH)
BROWN
SPARK TO PILOT IGNITER
HI
LO

Hide quick links: