Superior SVFS32NRK Owner's Operation And Installation Manual page 15

Unvented (vent-free) gas fireplace
Table of Contents

Advertisement

4. Attach the flexible gas line to gas supply
(see Figure 20). Check tightness of flex-
ible gas line attached to gas regulator of
fireplace (see Figure 20).
5. Check all gas connections for leaks. See
Checking Gas Connections.
6. Replace log base assembly back into
fireplace. Feed flexible gas line into fire-
place base area while replacing log base
assembly. Make sure the entire flexible
gas line is in fireplace base area. Reat-
tach log base assembly to fireplace with
screws removed in step 2, page 14.
CAUTION: Do not pick up
log base assembly by burner.
This could damage burner. Only
handle base by grates.
f i r e - p a r t s . c o m
Figure 19 - Removing Log Base
Assembly From Fireplace
To Fireplace Gas
Regulator
Flexible Gas Line
from Fireplace Gas
Regulator
Figure 20 - Attaching Flexible Gas Lines
Together
126543-01A
INSTALLATION
Equipment Shutoff
Valve Provided by
Installer
Propane/LP
To External
Regulator
Natural Gas
To Gas Meter
www.lennoxhearthproducts.com
Continued
NOTICE: Most building codes
do not permit concealed gas
connections. A flexible gas line
is provided to allow accessibility
from the fireplace (see Figure 20).
The flexible gas supply line con-
nection to the equipment shutoff
valve should be accessible.
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping
and connections, internal and
external to unit, for leaks after
installing or servicing. Correct
all leaks at once.
WARNING: Never use an
open flame to check for a leak.
Apply a noncorrosive leak detec-
tion fluid to all joints. Bubbles
forming show a leak. Correct all
leaks at once.
CAUTION: Make sure exter-
nal regulator has been installed
between propane/LP supply and
fireplace. See guidelines under
Connecting Fireplace to Gas
Supply, page 14.
PRESSURE TESTING GAS SUPPLY
PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)
1. Disconnect fireplace with its main gas
valve (control valve) and equipment shut-
off valve from gas supply piping system.
Pressures in excess of 1/2 psig will dam-
age fireplace regulator.
2. Cap off open end of gas pipe where equip-
ment shutoff valve was connected.
3. Pressurize supply piping system by either
opening propane/LP supply tank valve
for propane/LP gas or opening main gas
valve located on or near gas meter for
natural gas, or using compressed air.
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Svfs32prkSvfs36nrkSvfs36prk

Table of Contents