Viessmann VITOPLANAR Installation And Operating Instructions Manual

Viessmann VITOPLANAR Installation And Operating Instructions Manual

Wireless room temperature controller, lcd with clock and 7-day program
Hide thumbs Also See for VITOPLANAR:

Advertisement

Quick Links

Installation and
VIESMANN
operating instructions
Wireless room temperature controller,
LCD with clock and 7-day program
VITOPLANAR wireless thermostat LCD clock
6136715 GB
7/2018

Advertisement

Table of Contents
loading

Summary of Contents for Viessmann VITOPLANAR

  • Page 1 Installation and VIESMANN operating instructions Wireless room temperature controller, LCD with clock and 7-day program VITOPLANAR wireless thermostat LCD clock 6136715 GB 7/2018...
  • Page 2: Safety Instructions

    (e.g. by removing a separate fuse or by means of a mains isolator) and safeguard against unauthorised reconnection. Repairing components that fulfil a safety function can compromise the safe operation of the system. For replacements, use only original spare parts supplied or approved by Viessmann.
  • Page 4: Product Information

    Product information The appliance is a wireless room temperature controller with clock for capturing the temperature in residential, office and hotel rooms. Simple to install – no time-consuming chase cutting and plastering for cable routing. The controller can be installed on a flush mounted or surface mounted box on the wall.
  • Page 5: Installation

    Installation...
  • Page 6: Operating And Display Elements

    Operating and display elements AUTO mode  Comfort mode  Setback mode  Temperature Frost protection setting  mode Set the date and time /  programming Time   Measured temperature or  set temperature Current set temperature  Wireless transmission ...
  • Page 7 Assigning wireless receivers...
  • Page 8 Configuration >5s -5 °C -> +5 °C The thermostat must be switched off. Press the second button from the left for 5 seconds.  The thermostat version appears on the display. Press OK.  Menu CF01 appears on the display. Select the required setting with + and -.
  • Page 9 Configuration (continued)
  • Page 10 Configuration (continued) CF08 – Open detection function Deactivated Activated If the receiver is combined with an open detector (e.g. for a window), the heating is switched to frost protection mode when the window is opened. CF09 – Presence detection function Deactivated Activated If the receiver is combined with a motion detector, the temperature...
  • Page 11 Configuration (continued) CF12 – Time format 12 h (a.m./p.m.) 24 h CF13 – Automatic summer/wintertime changeover Deactivated Activated If CF13 = 0, the option to set the date is not offered. CF15 – Display of window symbol (open detection) If CF08 = 1: Non-flashing symbol Flashing symbol CF16 –...
  • Page 12 Configuration (continued)
  • Page 13 Configuration (continued) CF 28 – "Adaptive start control" function Thanks to this function, the required temperature is reached at the scheduled time. Function deactivated Function activated Press +/– to activate or deactivate the function. Confirm with OK. You will be taken to menu CF29. CF29 –...
  • Page 14 Entering the date and time...
  • Page 15 Defining set temperatures If you remain in one of these operating modes, the thermostat is permanently set to this temperature range (no programming). 6.1 Selecting the set comfort value Turn the selector switch to  (configuration CF10). Set the comfort temperature ...
  • Page 16: Display Features

    Defining set temperatures (continued) 6.4 Display features When selecting the set values, depending on the thermostat model and the selected set temperature, the screen colour may change, or a set of different colours may be shown. Green up to 19 °C (low consumption) Orange from 19.5 °C to 24°C (average consumption) Red from 24.5 °C to max.
  • Page 18 Programming...
  • Page 19 Programming (continued)
  • Page 20: Automatic Mode

    Automatic mode In AUTO mode, the thermostat is controlled according to the day program. The symbol indicates a heat demand (configuration CF16). The automatic program can be temporarily cancelled through: - "Party mode" – special enabling ( - Absence mode ( - Detection of open windows (symbol ), if this function has been activated (configuration CF08).
  • Page 21: Party Mode

    Party mode...
  • Page 22: Absence Mode

    Absence mode...
  • Page 23 External program interruption The external program interruption enables an external wireless transmitter, which also has this program interruption function, to interrupt the automatic operation of the thermostat. If the program is interrupted externally, the symbol and the new set temperature are displayed. The thermostat is controlled according to the parameters required by the external wireless transmitter.
  • Page 24: Displaying Information

    Displaying information The Info button serves to display the following information: - Current measured temperature or current set temperature (depending on configuration) - Outdoor temperature (if an outdoor temperature sensor has been assigned to the receiver) - Total consumption of assigned heating elements (configuration CF18) Press the button repeatedly to display the...
  • Page 25: Locking Settings

    Locking settings From one of the operating modes AUTO, Press the button for 5 seconds. The following symbol appears on the display. In locked mode, only the buttons On/Off ( ) and Info ( ) are accessible. To unlock, press the i button for 5 seconds >5s again.
  • Page 26: Resetting Settings

    Resetting settings...
  • Page 27 Resetting settings (continued)
  • Page 28 Deleting wireless assignment...
  • Page 29: Changing The Batteries

    Changing the batteries If this symbol is displayed, you have about 3 months until the battery will need changing (see technical information). Help • The following symbol appears on the display The batteries have run out. Replace the batteries • Receiver does not receive dat a from the thermostat. The wireless range may be insufficient.
  • Page 30: Specification

    Specification Power supply 2 batteries 1.5 V type LR03/AAA (CF05=0) Service life under normal use: Alkaline: 5 years Lithium: 10 years Protection class Radio frequency 868 MHz, class I (EN 300 220 standard) Wireless range 100 to 300 m in a free field, depending on appliance combination (subject to installation location and possible electromagnetic interference)
  • Page 31: Disposal Of Packaging

    Disposal of packaging Your contractor will dispose of the packaging from your Viessmann product. DE: Packaging waste is sent to a certified disposal contractor for recycling in line with statutory regulations. AT: Packaging waste is sent to a certified disposal contractor for recycling in line with statutory regulations.
  • Page 32: Declaration Of Conformity

    DE: www.viessmann.de/eu-conformity AT: www.viessmann.at/eu-conformity CH: www.viessmann.ch/eu-conformity-de www.viessmann.ch/eu-conformity-fr Viessmann Ges.m.b.H. A-4641 Steinhaus bei Wels Telephone: 07242 62381-110 Fax: 07242 62381-440 www.viessmann.at Viessmann Werke GmbH & Co. KG D-35107 Allendorf Telephone: +49 (0)6452 70-0 Fax: +49 (0)6452 70-2780 www.viessmann.de...