Management guide

Access the management interface of the
Switch
This section instructs you how to enter and proceed the advanced
management capability, which can be accessed through console port or
Telnet session / Internet Browser over the network (in-band).

Manage the device via command line interface

To start-up the command line interface, please connect a PC COM port to
the RS-232 connector and activate a terminal emulation software (e.g.
HyperTerminal of Windows.)
The terminal emulation software should be started as the following
configuration:
1.
Data rate: 115200 baud
2.
Data format: 8 data bits, 1 stop bit and no parity
3.
Flow control: none.
4.
Click the property icon, select settings, make sure that:
5.
"The Function, arrow, and ctrl keys act as": Terminal keys
"Emulation": VT100
Note: To manage via command line interface, please find the "Appendix" for
more information

Manage the device via WEB browser

To access the Web-based management interface, you should configure the
management station with an IP address and subnet mask that compatible to
your switch.
The factory default value of the switch:
IP:
Subnet Mask:
Default Gateway:
192.168.1.1
255.255.255.0
192.168.1.254