T
roubleshooting
Reduced spray oR no spray
possible causes
1. Solution tank empty
2. Lint screen on solution tank cap clogged
3. Spray nozzle clogged
4. Upper handle is not in the upright and locked position
5. Upper body not attached properly
deep cleaner not picking up cleaning solution
possible causes
1. Collection tank not aligned/secured
2. Collection tank full
3. Removable nozzle installed improperly
4. Removable nozzle full of debris
5. Red lint screen under collection tank clogged
other maintenance or service not included in the manual should be
performed by an authorized service representative.
thank you for selecting a bissell product.
please do not return this product to the store.
w w w . b i s s e l l . c o m
Remedies
1. Refill tank with water and formula
2. Soak solution tank cap in warm water and then rinse under
running water
3. Clean spray nozzle by rinsing under water
4. Rotate the retractable handle lock, pull handle up and return
the handle lock to the locked position.
5. Repeat steps 2-4 on page 5.
Remedies
1. Check tank alignment and secure with side latches
2. Empty tank
3. Unplug unit. Align two "hooks" into bottom first, then snap
into place on top
4. Unplug unit. Remove nozzle and rinse under running water
5. Remove debris from lint screen