Section 2: Getting Started; Installation Steps; Terminal Descriptions - DSC PC5008 Installation Manual

Hide thumbs Also See for PC5008:
Table of Contents

Advertisement

The following sections provide a thorough description of how to
wire and configure devices and zones.
2.1

Installation Steps

Read this section completely before you begin. Once you have
an overall understanding of the installation process, carefully
work through each step.
Step 1: Create a Layout
Draw a rough sketch of the building to get an idea of where all
alarm detection devices, keypads and other modules are to be
located.
Step 2: Mounting the Panel
Locate the panel in a dry area close to an unswitched AC power
source and the incoming telephone line. Before attaching the
cabinet to the wall, be sure to press the four circuit board
mounting studs into the cabinet from the back. After you have
attached the cabinet to the wall, stick the provided DSC logo
sticker on the front of the cabinet.
You must complete all wiring before connecting
the battery, or applying AC to the panel . . . . .
Step 3: Wiring the Keybus (Section 2.3)
Wire the Keybus to each of the modules following the guidelines
provided in Section 2.3 of this manual.
Step 4: Zone Wiring (Section 2.8)
You must power down the control panel to complete all zone
wiring. Please refer to Section 2.8 when connecting zones using
normally closed loops, single EOL resistors, double EOL resistors,
Fire zones and Keyswitch Arming zones.
Step 5: Complete Wiring (Section 2.2)
Complete all other wiring including bells or sirens, telephone
line connections, and ground connections following the
guidelines provided in Section 2.2 ("Terminal Descriptions").
Step 6: Power up the Control
Once all zone and Keybus wiring is complete, power up the
control panel. First, connect the red battery lead to the positive
terminal and the black lead to negative. Then, connect the AC.
Connect the battery before connecting the AC.
The panel will not power up on the battery
connection alone.
Step 7: Keypad Assignment (Section 2.5)
In order for keypads to be properly supervised, each must be
assigned to a different slot. Please follow the guidelines provided
in Section 2.5 when assigning keypads.
Step 8: Supervision ( Section 2.6 )
The supervision of every module by the panel is automatically
enabled upon power up. Please verify that all modules appear
on the system according to the instructions in Section 2.6.
Step 9: Programming the System (Sections 4 and 5)
Section 4 explains how to program the panel. Section 5 contains
a complete description of the various programmable features,
which options are available and how they function. The
Programming Worksheets should be filled out completely before
attempting to program the system.
Getting Started
S
E
C
T
3
I
O
N
2
Step 10: Testing the System
The panel must be thoroughly tested to ensure that all features
and functions are operating as programmed.
2.2

Terminal Descriptions

Battery Connection
A 12V 4Ah rechargable battery is used as a backup source of
power in the event of an AC power failure. The battery also
provides additional current when the panel's demands exceed
the power output of the transformer, such as when the panel is
in alarm.
The High Current Charge/Standard Battery Charge option
(section [701], option [7]) allows you to choose between a high
current battery charge and the standard battery charge rate.
Do not connect the battery until all other wiring is
complete. Connect the battery before connecting
the AC.
Connect the RED battery lead to the positive battery terminal;
connect the BLACK lead to negative.
AC Terminals – AC
The panel requires a 16.5 volt, 40VA transformer. Connect the
transformer to an unswitched AC source and connect the
transformer to these terminals.
The panel can be programmed to accept a power line frequency
of either 50Hz AC or 60Hz AC in programming section [701],
option [1].
Do not connect the transformer until all other
wiring is complete . . . . .
Auxiliary Power Terminals – AUX+ and AUX-
These terminals provide up to 550 mA of additional current at 12
V
for devices requiring power. Connect the positive side of
DC
any device requiring power to the AUX+ terminal, the negative
side to AUX- (ground). The AUX output is protected. This means
that if too much current is drawn from these terminals (such as
a wiring short), the panel will temporarily shut off the output until
the problem is corrected.
Bell Output Terminals – BELL+ and BELL-
These terminals provide up to 700 mA of continuous current at
12 V
for powering bells, sirens, strobes or other warning-type
DC
equipment. Connect the positive side of any alarm warning
device to BELL+, the negative side to BELL–. Please note that
the Bell output is protected: if too much current is drawn from
these terminals (such as a wiring short), the Bell PTC will open.
Three amps can be drawn for short periods only.
The Bell output is supervised. If no alarm warning devices are
in use, connect a 1000Ω resistor across BELL+ and BELL– to
prevent the panel from displaying a trouble condition. For more
information, please refer to Section 3.4 ("[ ] [2] Trouble Display").
Keybus Terminals – AUX+, AUX-, YEL, GRN
The Keybus is used by the panel to communicate with modules
and vice versa. Each module has four Keybus terminals that
must be connected to the four Keybus terminals on the panel.
For more information, see Section 2.3 ("Keybus Operation and
Wiring").