ELECTRICAL CONNECTIONS ON FIREPLACE
When connecting to the fireplace See illustrations below and also
on pg22 for clarity.
Supply and Vent Fan
Straight color for color matching.
BLACK
WHITE
GREEN
Remove the rear panel and flue box of the Power-Vent
by removing the six #10-24 X 3/8 inch screws shown in
the figure below.
30
VENT FRAMING AND FINISHING
L
BLACK (Live/Hot)
N
WHITE (Neutral)
G
GREEN (Ground/Earth)
120VAC
VENT
MAINS
FAN
SUPPLY (IN)
(OUT)
Remove (6) Screws
Insert the straight side of the main harness through the 7/8
inch hole in the rear panel of the Power-Vent and secure
with nut. Connect the black and white wire to the terminals
on the inducer motor as shown in the figure below.
Remove the top #10 X 1/2 inch screw on the front of the
flue box and attach the green wire from the main harness
and the green/yellow wire from the inducer motor with the
screw as shown in the figure that follows.
Re-attach the rear panel and flue box to the Power-Vent
outer box with six #10 X 3/8 inch screws.