Separate type · digital sensor controller
DPC-L100 Sereis
Thank you very much for purchasing Panasonic products.
Read this Instruction Manual carefully and thoroughly for the correct and optimum
use of this product.
Kindly keep this manual in a convenient place for quick reference.
WARNING
Never use this product as a device for personnel protection.
In case of using devices for personnel protection, use products which
meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel
protection applicable in each region or country.
The product for use inside Japan complies with Japanese Measurement
Laws. Avoid using the product model for outside of Japan within Japan.
1
PART DESCRIPTION
Output 1 operation
indicator
Lights up when com-
parative output 1 is ON
Output 2 operation
indicator
Lights up when com-
parative output 2 is ON
Mode selection key
Set value UP key
Notes: 1) Attach the unit switch plate corresponds to the set pressure unit.
2) The product for use inside Japan can be set only to "MPa" or "kPa."
2
MOUNTING
T h e s e n s o r m o u n t i n g b r a c k e t
MS-DP1-6 is available as an option.
When mounting the sensor onto the
sensor mounting bracket, etc., the tight-
ening torque should be 0.5N·m or less.
T h e p a n e l m o u n t i n g b r a c k e t
MS-DP1-2 (optional), as well as the
front cover MS-DP1-3 (optional) are
also available.
For mounting of the panel mounting
bracket, refer to the Instruction Manual
enclosed with MS-DP1-2.
3
CONNECTION OF PRESSURE SENSOR HEAD
In case of initial set up or reset, select pressure range.
incase changing pressure sensor head, check pressure range.
Connection method
1. Insert the pressure sensor head cable into the
product's connector area for the pressure sen-
VRU KHDG DV VKRZQ LQ WKH ULJKW ¿JXUH
Disconnection method
1. Pressing the release lever of the pressure sen-
sor head cable, pull out the connector.
Note: Do not pull by holding the cable without pressing the re-
lease lever, as this can cause cable break or connector
break.
<Terminal pin arrangement>
Terminal pin No.
1
Sensor head supply voltage
2
3
1 2 3 4
4
4
WIRING
Connection method
1. Insert cable with connector &1$&
the product's connector area for a power / I-O
FDEOH DV VKRZQ LQ WKH ULJKW ¿JXUH
Disconnection method
1. Pressing the release lever of the cable with con-
nector, pull out the connector.
Note: Do not pull by holding the cable without pressing the release
lever, as this can cause cable break or connector break.
<Terminal pin arrangement>
Terminal pin
Terminal name
No.
1
Analogue voltage
2
1 2 3 4 5
6
/ current output
3
Ramco National
INSTRUCTION MANUAL
For liquid / gas
MJE-DPCL100 No. 0040-92V
Connector area for a
power supply / I-O cable
Attach area for
unit switch plate
(Note 1, 2)
Main display
Sub display
Set value
DOWN key
Connector area for a
pressure sensor head
M3 (length 6mm)
screws with washers
Accessory with
MS-DP1-6
Sensor mounting bracket
MS-DP1-6 (Optional)
Pressure
sensor
head cable
Release lever
<Connector area of the pressure sensor head cable>
e-con: 1473562-4
[Tyco Electronics AMP G.K.]
Terminal name
Analogue input
0V
Not used
Cable with
connector
CN-66A-C
into
Release lever
<Connector area of the cable with connector>
Housing: PAP-06V-S
[JST Mfg. Co., Ltd.]
Terminal pin
Terminal name
No.
+V
4
Comparative output 1
5
Comparative output 2
0V
6
External input
800-280-6933 | nsales@ramcoi.com
5
I/O CIRCUIT DIAGRAMS
NPN output type
(Brown) +V
(Gray) Analogue
voltage / current
output (Note 1, 2, 3)
(Black) Comparative output 1
(White) Comparative output 2
(Pink) External input
(Blue) 0V
PNP output type
(Brown) +V
(Pink) External input
(Black) Comparative output 1
(White) Comparative output 2
(Gray) Analogue
voltage / current
output (Note 1, 2, 3)
(Blue) 0V
*1
Non-voltage contact, NPN transistor or
DC 2-wire output
or
High (5 to 30V DC or Open): Invalid
Low (0.4V DC or less): valid
1RWHV  :KHQ WKH DQDORJXH FXUUHQW LV RXWSXW WKH RXWSXW ORDG UHVLVWDQFH VKRXOG EH Ÿ PD[
2) Take care that when the analogue current is output, 5V or more voltage generates.
3) When using the analogue voltage output, be careful to the input impedance of the connected device.
Furthermore, note that if the cable is extended, the cable resistance will cause the voltage to drop.
6
OUTPUT MODE AND OUTPUT OPERATION
The EASY mode, hysteresis mode or window comparator mode can be se-
lected as the output mode for comparative output 1 and comparative output
2. Refer to <Comparative output 1 / 2 output mode setting> in "
SETTING MODE" for details.
EASY mode
ON / OFF of the comparative output is controlled in this mode.
H (Hysteresis)
P
0
Comparative
ON
output
OFF
1RWHV  +\VWHUHVLV FDQ EH ¿[HG LQ  VWHSV
Refer to <+\VWHUHVLV ¿[HG YDOXH VHOHFWLRQ> in "
2) "
" is displayed for comparative output 1 and "
Hysteresis mode
The comparative output ON / OFF state can be controlled with randomly set
hysteresis in this mode.
Hi
H (Hysteresis)
Lo
ON
Comparative
OFF
output
Notes: 1) "
" or "
" is displayed for comparative output 1 and "
parative output 2 on the sub display.
Window comparator mode
In this mode, the ON or OFF state of the comparative output is controlled with
a pressure in the set range.
H (Hysteresis)
Hi
Lo
Comparative
ON
output
OFF
1RWHV  +\VWHUHVLV FDQ EH ¿[HG LQ  VWHSV
Refer to <+\VWHUHVLV ¿[HG YDOXH VHOHFWLRQ> in "
2) "
" or "
" is displayed for comparative output 1 and "
parative output 2 on the sub display.
 6HW WKH LQWHUYDO EHWZHHQ WKH /R VLGH DQG +L VLGH WR K\VWHUHVLV ¿[HG YDOXH RU PRUH
Load
Load
+
12 to 24V DC
±10%
-
(*1)
(*2)
+
12 to 24V DC
±10%
-
Load
Load
*2
Non-voltage contact, PNP transistor or
DC 2-wire output
or
High (5 to +V DC or Open): valid
Low (0.6V DC or less): Invalid
+ +\VWHUHVLV ¿[HG 1RWH 
PRO MODE" for setting.
" for comparative output 2 on the sub-display.
H: 1 digit or more
When using psi unit model for out-
side of Japan, it is 2 digits or more.
However, the 50MPa pressure
range model is 20 digits or more.
" or "
" is displayed for com-
+ +\VWHUHVLV ¿[HG 1RWH 
H (Hysteresis)
PRO MODE" for setting."
" or "
" is displayed for com-
www.panasonicsensors.com
MENU

Advertisement

loading

Summary of Contents for Panasonic DPC-L100 Series

  • Page 1 (Black) Comparative output 1 MJE-DPCL100 No. 0040-92V ±10% (White) Comparative output 2 Thank you very much for purchasing Panasonic products. (Pink) External input Read this Instruction Manual carefully and thoroughly for the correct and optimum (*1) use of this product.
  • Page 2 SETTING WHEN TURNING ON THE POWER MENU SETTING MODE After turning ON the power, set pressure range of pressure sensor head con- The mode will change to RUN mode when the mode selection key is held nected to this product. The set pressure range is memorized and the range is down during this setting process.
  • Page 3 PRO MODE Code table 0DLQ GLVSOD\ ¿UVW GLJLW IRUP OHIW The mode will change to RUN mode when the mode selection key is held 1st digit 2nd digit 3rd digit 4th digit down during this setting process. However, changed items before holding Comparative Comparative N.O.
  • Page 4 Take care that if a voltage exceeding the rated range is applied, or if an AC Contact for CE power supply is directly connected, the product may get burnt or damaged. Panasonic Marketing Europe GmbH Panasonic Testing Center Take care that wrong wiring will damage the sensor. Winsbergring 15, 22525 Hamburg,Germany Do not run the wires together with high-voltage lines or power lines or put them in the same raceway.

This manual is also suitable for:

Dpc-l101zDpc-l101Dpc-l101z-pDpc-l101-p