7
SETTING WHEN TURNING ON THE POWER
After turning ON the power, set pressure range of pressure sensor head con-
nected to this product. The set pressure range is memorized and the range is
displayed every time after tuning on the power. Then, move to RUN mode.
In case replacing sensor head or resetting it, set the pressure range again.
Turning ON the power
Pressure range
setting
-0.1 to 1MPa
0 to 1MPa
Check the set
pressure range
Resetting the
&RQ¿UP WKH VHW
pressure range
pressure range
The set pressure range is displayed.
8
RUN MODE
Setting the threshold value
Refer to <Comparative output 1 / 2 output mode setting> in "
SETTING MODE" for setting conditions.
The Sub display conducts the threshold value. Main display does not changed.
Display is changed by pressing down.
EASY mode
(Comparative output 2 is OFF)
Comparative
output 1
EASY mode
Comparative
output 2
Comparative
Hysteresis mode / Window
output 1
comparator mode · Lo side
Comparative
output 2
Comparative
output 1
Hysteresis mode / Window
comparator mode · Hi side
Comparative
output 2
Notes: 1) If the set pressure range is exceeded, "
limit) will appear on the sub display. "
Lo side threshold value when setting the "hysteresis mode / window comparator mode" threshold value.
2) Auto-reference value and remote zero-adjustment value are displayed.
For details, refer to "
AUTO-REFERENCE FUNCTION" and "
FUNCTION."
3) In the dash line box is not displayed when not setting "
setting method, refer to<Function setting> in "
Zero-adjustment function
The zero-adjustment function forcibly sets the pressure value to "zero" when
the pressure port is opened.
Hold down
1RWH (YHQ LI WKH ]HURDGMXVWPHQW LV FRQGXFWHG WKH DQDORJXH YROWDJH  FXUUHQW RXWSXW LV QRW LQÀXHQFHG
Key lock function
The key lock function prevents key operations so that the conditions set in
each setting mode are not inadvertently changed.
<Key lock set>
Hold down
<Key lock released>
Hold down
Peak / bottom hold function
The peak / bottom hold functions display the peak value and bottom value of
WKH ÀXFWXDWLQJ SUHVVXUH
PEAK / BOTTOM HOLD FUNCTION. "
For detail, refer to "
The peak value is displayed on the main display and the bottom value is dis-
played on the sub display.
the higher vacuum side indicates the peak value, while the lower vacuum side
indicates the bottom value.
<Peak / bottom hold set>
Hold down
<Peak / bottom hold released>
Hold down
Ramco National
0 to 3.5MPa
0 to 10MPa
0 to 50MPa
RUN mode
MENU
Automatic
Press down: increase threshold value to high pressure side.
Press down: decrease threshold value to low pressure side.
Blinks alternately
(Note 2)
(Note 3)
" (exceeds the upper limit) or "
" (exceeds the lower
" will also appear if the Hi side threshold value exceeds the
REMOTE ZERO-ADJUSTMENT
" or "
" in external input switch. For the
MENU SETTING MODE."
Automatic
Automatic
Automatic
Blinks alternately
800-280-6933 | nsales@ramcoi.com
9
MENU SETTING MODE
The mode will change to RUN mode when the mode selection key is held
down during this setting process. In doing so, changed items before holding
down the mode selection key have been set.
RUN mode
Press for 2 sec.
<Comparative output 1 output mode setting>
Hysteresis
Window com-
EASY mode
mode
parator mode
<Comparative output 2 output mode setting>
Hysteresis
OFF mode
EASY mode
mode
<N.O. / N.C. selection> (When the comparative output 2 output mode setting is set to OFF)
N.O.
N.C.
<N.O. / N.C. selection> (When the comparative output 2 output mode setting is set to other than OFF)
Output 1: N.O.
Output 1: N.C.
Output 1: N.O.
Output 2: N.O.
Output 2: N.C.
Output 2: N.C.
<Analogue voltage / current output selection>
Analogue
Analogue
voltage
current out-
output mode
put mode
<Function setting>
Remote zero-
Auto-reference
adjustment
OFF
function mode
function mode
<Response time setting>
5ms
10ms
<Display color selection of the main display>
Red when ON
Green when ON
Green when OFF
Red when OFF
Always red
<Unit selection> (Note 1)
2
MPa
kPa (Note 2)
kgf/cm
<RUN mode>
Note: 1) In case connecting pressure range 1MPa type of pressure sensor head to Japanese model controller,
only "MPa" or "kPa" can be set. Also, in case connecting 3.5MPa or more type, setting item for unit
change is not displayed.
2) in case of connecting pressure range 3.5MPa type of sensor head to out side of japan type controller.
"
" is not displayed.
Setting Item
Factory setting
Comparative
output 1 output
Sets comparative output 1 output mode.
mode setting
Comparative
output 2 output
Sets comparative output 2 output mode.
mode setting
N.O. / N.C.
Sets when Nomal Open (N.O.) or Normal Close (N.C.).
selection
Initial state of excepting OFF of the comparative output 2 setting is "
Analogue voltage
/ current output
Selects Analogue voltage output or analogue current output.
selection
Sets Auto-reference function or remote zero-adjustment function and current
Function setting
value hold function or peak / bottom 2 function.
Sets response time.
Response time
The response time can be select from 5ms, 10ms, 25ms, 50ms, 100ms,
setting
250ms, 500ms, 1,000ms or 5,000ms.
Display color
selection of the
Selects display coler of main display.
main display
Unit selection
Selects pressure unit.
Window
comparator
mode
Output 1: N.C.
Output 2: N.O.
Current
Auto-peak /
value hold
bottom hold
function
2 function
5,000ms
Always green
bar
psi
Description
www.panasonicsensors.com
."

Advertisement

loading

This manual is also suitable for: