Fuel Specifications

NOTICE
Natural gas and propane installations must be
installed in accordance with applicable federal,
state, and local law, and with the National Fire
Protection Association (NFPA) Pamphlet #58,
standard for storage and handling of Liquefied
Petroleum Gases, to the extent that these
standards are not in violation of federal, state, or
local law.
Fuel Type
Liquid Propane
Type
Gas (LPG)
Maximum fuel pressure
(engine OFF, no load)
Minimum fuel pressure
(engine ON, full load)
Natural Gas (NG)
Supply
Approximate supply volume
Minimum flow
Allowable water vapor
Maximum fuel pressure
(engine OFF, no load)
Minimum fuel pressure
(engine ON, full load)
LPG and NG
Fuel handling and supply
(both)
component constraints
Operating temperature range
TP-6901 3/16a
Table 4-1: Fuel Specifications
Item
HD-5 or HD-10
11.0" W.C.
5.0" W.C.
Standard pipeline
37.257 kJ/m
11.9 m
@ 5.0" W.C.
Less than 112.3 kg per 1 million m
(Less than 7 lb. per 1 million ft.
11.0" W.C.
5.0" W.C.
UL 2200: Standard for Stationary Engine Equipment
Assemblies
–20°C (–4°F) to 105°C (221°F)
Specification
KG2204
3
3
(1000 BTU/ft.
)
3
/hr. (420 SCFH)
19.6 m
@ 5.0" W.C.
3
OPERATION
KG2204T
3
/hr. (690 SCFH)
3
)
Operation 19