1.Thermostat at the combustion chamber 2. Protection against overheating 3. Overflow protection
9. Operation of the heaters
YOU MUST NOT ADD OIL TO THE FURNACE AND FIRE IT WHEN
THE CHAMBER OR PAN OF THE FURNACE IS STILL HOT!!!
ALWAYS WAIT UNTIL THE BURNER PLATE IS TOTALLY COOLED
OFF. FAILURE TO OBSERVE THE ABOVE-MENTIONED
RECOMMENDATION CREATES A RISK OF UNCONTROLLED
IGNITION OF OIL VAPOURS AND BURNING!!!
Starting the device
After the heater, it goes through the respective operating conditions depending on the settings introduced
by the user and the information received from the sensors attached to the controller system.
- in case of emergency, discharge the water from the fuel tank and fill it in with used oil
- put the plug of the power cable into the mains socket (230V 50Hz)
- open the top part of the heater housing and remove the cover of the combustion chamber, then take out
the cylinder and ring (in the case of necessity, clean the combustion pan and base on which it is placed,
but also the whole combustion chamber with a sleeve and the ring)
- check whether the furnace pan is cool and clean, then pour about 250 ml of fuel oil or diesel oil
- fire the oil, using a piece of paper which is crumpled into a ball for this purpose. the piece of paper must
be set afire and thrown onto the furnace pan
- mount the ring and the cylinder, place the combustion chamber cover, close the top part of the heater
housing
- press the Start button on the control panel (a green diode will be back-lit)
- after about 10-15 minutes, depending on the room temperature, the fuel pump and the fan will be
switched on, and at the same time, the yellow diode for pump operation will be back-lit, the furnace
will start to operate on the first gear with a decreased efficiency (22 kW; burning 1.85 kg/h), it may
operate continuously in this condition, the second gear with an increased efficiency (30 kW: burning
2.55 kg/h) may be switched on (marked with "+" symbol) after 30 minutes from the start of the
operation of the furnace.
Each pressing the Stop button and pressing the Start button again and again during its
operation will cause the furnace to be lit off.
Switching off the device
- press the Stop button on the control panel (the yellow diode is not back-lit anymore), the pump stops
supplying fuel on the combustion pan, the fan operates until the furnace is cooled off.