Summary of Contents for Desa RM200T

  • Page 1 FORCED AIR HEATER (WITH BUILT-IN THERMOSTAT) OWNER’S MANUAL 200,000 Btu/Hr Model RM200T IMPORTANT: Read and understand this manual before assembling, start- ing, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. ®...
  • Page 2: Safety Information

    • Keep children and animals away from heater. • Unplug heater when not in use. • Heater is equipped with a thermostat. Heater may start anytime. • Never use heater in living or sleeping areas. • Never block air inlet (rear) or air outlet (front) of heater.
  • Page 3: Product Identification

    PRODUCT IDENTIFICATION Hot Air Outlet Lower Shell Fuel Cap Side Cover Figure 1 - RM200T Model 103607 OWNER’S MANUAL Upper Shell Fan Guard Flame-out Control Power Cord Reset Button Thermostat Knob UNPACKING Remove all packing items applied to heater for shipment.
  • Page 4: Tools Needed

    200,000 BTU/HR PORTABLE FORCED AIR HEATER ASSEMBLY This model is furnished with wheels and handles. Wheels, handles, and the mounting hardware are found in the shipping carton. TOOLS NEEDED • Medium Phillips Screwdriver • 3/8" Open or Adjustable Wrench • Hammer 1.
  • Page 5: Theory Of Operation

    Plug extension cord into standard 120 volt/60 hertz, three-hole, grounded out- let. Adjust thermostat to desired setting. If heater does not start, thermostat set- ting may be too low. Turn thermostat knob to higher position to start heater. If thermostat is in HIGH position and heater still will not start, push in flame- out control reset button (see Figure 4).
  • Page 6: Storing, Transporting, Or Shipping

    200,000 BTU/HR PORTABLE FORCED AIR HEATER STORING, TRANSPORTING, OR SHIPPING Note: If shipping, transport companies re- quire fuel tanks to be empty. 1. Drain fuel tank. Note: This model has a drain plug on underside of fuel tank. Remove drain plug to drain all fuel.
  • Page 7: Troubleshooting

    TROUBLESHOOTING Note: For additional help, visit DESA International’s Technical Service web site at www.desatech.com. OBSERVED FAULT Heater ignites, but flame-out control shuts off heater after a short period of time Heater will not ignite, but motor runs for a short period of time...
  • Page 8: Service Procedures

    200,000 BTU/HR PORTABLE FORCED AIR HEATER SERVICE PROCEDURES WARNING: Never service heater while it is plugged in, op- erating, or hot. Severe burns and electrical shock can occur. UPPER SHELL REMOVAL 1. Remove screws along each side of heater using 5/16" nut-driver. These screws attach upper and lower shells together.
  • Page 9: Fuel Filter

    SERVICE PROCEDURES Continued FUEL FILTER 1. Remove side cover screws using 5/16" nut-driver. 2. Remove side cover. 3. Pull lower fuel line off the fuel valve fitting. 4. Carefully pry bushing, lower fuel line, and fuel filter out of fuel tank. 5.
  • Page 10: Spark Plug

    200,000 BTU/HR PORTABLE FORCED AIR HEATER SERVICE PROCEDURES Continued SPARK PLUG 1. Remove upper shell (see Upper Shell Removal, page 8). 2. Remove fan (see Fan, page 8). 3. Remove spark plug wire from spark plug (see Figure 12). 4. Remove spark plug and wave spring washer from burner head using 13/16"...
  • Page 11: Pump Rotor

    SERVICE PROCEDURES Continued Nozzle Face Nozzle Seal Nozzle Burner Head Fuel Line Air Line Fitting Fitting Figure 16 - Removing Nozzle 103607 OWNER’S MANUAL PUMP ROTOR (Procedure if Rotor is Binding) 1. Remove upper shell (see Upper Shell Removal, page 8). 2.
  • Page 12: Illustrated Parts Breakdown

    200,000 BTU/HR PORTABLE FORCED AIR HEATER ILLUSTRATED PARTS BREAKDOWN RM200T Burner Head Assembly 10-1 10-3 10-2 10-4 10-5 10-17 10-16 10-15 10-18 10-14 Motor and Pump Assembly 10-6 10-7 10-8 10-9 10-10 10-11 10-13 10-12 44-1 44-7 44-8 44-4 Fuel Valve Assembly...
  • Page 13: Parts List

    PARTS LIST RM200T PART NUMBER DESCRIPTION 098511-229 Upper Shell 100647-01 Screw, #10-16 x 1/2" 098512-48 Combustion Chamber 099229-01 Photocell Bracket M10908-2 Screw, #6-32 x 3/8" HA3019 Photocell Assembly Burner Head Assembly 100735-13 Nozzle M10659-1 Nozzle Washer M10809-1 Nozzle Spring M8882...
  • Page 14: Wheels And Handle Parts List

    TECHNICAL SERVICE You may have further questions about installa- tion, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323-5190. You can also visit DESA International’s Tech- nical Services web site at www.desatech.com. 200,000 13.5 3450 103607...
  • Page 15: Wiring Diagram

    Purchase accessories and parts from your nearest dealer or service center. If they can not supply these accessories or parts, either contact your nearest Parts Central or DESA International for referral information. Parts Centrals are listed in the Authorized Service Center booklet supplied with heater.
  • Page 16: Warranty And Repair Service

    LIMITED WARRANTY DESA International warrants this product and any parts thereof, to be free from defects in materials and workmanship for one (1) year from the date of first purchase when operated and maintained in accordance with instructions. This warranty is extended only to the original retail purchaser, when proof of purchase is provided.