Chapter 2 Preparations
16. Pass the cable below the cage, and set the additional fan unit.
17. Connect fan cable securely to HDDBP connector.
18. When the additional fan unit is installed, secure the battery tray for RAID Controller with a single
screw you have removed in Step 15.
19. Continue to install or remove internal optional devices, mount and connect the server, and turn it on.
20. Run BIOS Setup Utility (SETUP) to confirm the following settings. Refer to Chapter 2 (1. Details of
System BIOS) in "Maintenance Guide".
Advanced → Processor Configuration → Processor Information

Replacement / Removal

1.9.2
To remove processor (CPU), reverse the installation procedure.
[CPU ID]
[L2 Cache RAM]
[L3 Cache RAM]
Important
• Do not remove any processor unless it is failed.
• To remove the heat sink from the processor, first turn the heat sink to the left and
right lightly to make sure that the heat sink can be apart from the processor.
Removing the heat sink with it adhering to the processor may cause the
processor and/or CPU socket to be defected.
Express5800/R120d-1M User's Guide
1. Installing Internal Optional Devices
57