Installation; Indoor Unit; Wall Mounting Plate; Wall Penetration - Rinnai CJ Series Installation Manual

Hide thumbs Also See for CJ Series:
Table of Contents

Advertisement

INDOOR UNIT

Wall Mounting Plate

1�
The wall or structure on which the units are to be mounted must be capable of supporting the weight of the
appliance and the associated pipe-work�
2�
Fix the mounting plate on to the wall using, ensuring that it is both level and firmly mounted with the appropriate
fixings.
DO NOT install the unit in a place where electrical wiring or conduits are located�
CAUTION
HINCJ25B
A
B
C
D
294
881
228
84

Wall Penetration

Drill a Ø70mm wall penetration through the wall with a 2° to 4° fall to the outside wall�

Drain Pipe

1�
Connect the drain pipe to the drain hose outlet of the indoor unit,
2�
Bind the joint with PVC insulation tape (not supplied)�
Rinnai
B
Wall Mounting Plate Positioning Dimensions (mm)
HINCJ35B
E
A
B
C
D
43
316
940
218
54
INSIDE
D
Ø70
HINCJ50B
E
A
B
C
D
41
316
997
217
43
2° to 4° fall
OUTSIDE
9

INSTALLATION

A
C
E
HINCJ70B
E
A
B
C
38
330 1132 236
D
E
56
39
Split AC IM

Advertisement

Table of Contents
loading

Table of Contents