Modbus Map SOLECTRIA XGI 1500 (Rev A)
14

Inverter Restart

This feature allows inverter control MCU to reset. It will clear all the faults and restart the inverter.
Example:
If cutomer wants to reset and restart inverter, click "Restart" button via web-based GUI. After that, inverter
will stop producing power, reset MCU and restart itself.
The alternative method is to use software which supports Modbus TCP/IP. The register address is shown
below.
To implement the same step, the procedure is shown below.
 Write " 577 " to register 40921 for restarting inverter.