Table 2 Cooling Pressure - Bard W17A2-A Installation Instructions Manual

Wall mounted packaged
Table of Contents

Advertisement

Return Air Temp
Model
(DB/WB)
75/62
W17A/L
80/67
85/72
75/62
W18A/L
80/67
85/72
75/62
W24A/L
80/67
85/72
75/62
W30A/L
80/67
85/72
75/62
W36A/L
80/67
85/72
75/62
W42A/L
80/67
85/72
75/62
W48A/L
80/67
85/72
75/62
W60A/L
80/67
85/72
75/62
W70A/L
80/67
85/72
Low side pressure ± 4 PSIG
High side pressure ± 10 PSIG
Tables are based upon rated CFM (airflow) across the evaporator coil. If there is any doubt as to correct operating charge
being in the system, the charge should be removed, system evacuated and recharged to serial plate charge weight.
NOTE:
Pressure table based on high speed condenser fan operation. If condensing pressures appear elevated check
condenser fan wiring. See "Condenser Fan Operation".
TABLE 2
Cooling Pressure
Pressure
75
80
85
Low Side
124
126
128
High Side
321
340
362
Low Side
133
135
137
High Side
329
349
371
Low Side
138
140
142
High Side
341
361
384
Low Side
127
129
131
High Side
318
339
362
Low Side
136
138
140
High Side
326
348
371
Low Side
141
143
145
High Side
337
360
384
Low Side
119
121
122
High Side
340
361
383
Low Side
127
129
131
High Side
349
370
393
Low Side
131
134
136
High Side
361
383
407
Low Side
122
124
127
High Side
335
358
381
Low Side
130
133
136
High Side
344
367
391
Low Side
135
138
141
High Side
356
380
405
Low Side
120
122
124
High Side
339
366
392
Low Side
128
130
133
High Side
348
375
402
Low Side
132
135
138
High Side
360
388
416
Low Side
123
124
126
High Side
320
342
367
Low Side
132
133
135
High Side
328
351
376
Low Side
137
138
140
High Side
339
363
389
Low Side
117
119
121
High Side
355
378
403
Low Side
125
127
129
High Side
364
388
413
Low Side
129
131
134
High Side
377
402
427
Low Side
122
124
126
High Side
346
371
396
Low Side
131
133
135
High Side
355
380
406
Low Side
136
138
140
High Side
367
393
420
Low Side
118
121
122
High Side
349
371
395
Low Side
126
129
131
High Side
358
381
405
Low Side
130
134
136
High Side
371
394
419
Air Temperature Entering Outdoor Coil °F
90
95
100
105
110
130
132
133
135
137
384
409
434
461
490
139
141
142
144
146
394
419
445
473
503
144
146
147
149
151
408
434
461
490
521
133
135
137
138
140
385
409
434
459
486
142
144
146
148
150
395
419
445
471
498
147
149
151
153
155
409
434
461
487
515
124
127
129
131
133
407
432
459
488
518
133
136
138
140
142
417
443
471
500
531
138
141
143
145
147
432
459
487
518
550
129
131
133
135
137
406
431
456
483
509
138
140
142
144
146
416
442
468
495
522
143
145
147
149
151
431
457
484
512
540
126
129
130
132
134
418
446
473
501
529
135
138
139
141
143
429
457
485
514
543
140
143
144
146
148
444
473
502
532
562
128
130
132
134
136
391
416
443
469
496
137
139
141
143
145
401
427
454
481
509
142
144
146
148
150
415
442
470
498
527
123
125
127
129
131
427
454
482
510
539
132
134
136
138
140
438
466
494
523
553
137
139
141
143
145
453
482
511
541
572
128
130
131
133
135
421
447
473
499
526
137
139
140
142
144
432
458
485
512
539
142
144
145
147
149
447
474
502
530
558
123
125
127
129
131
419
444
470
497
525
132
134
136
138
140
430
455
482
510
538
137
139
141
143
145
445
471
499
528
557
115
120
138
140
521
553
148
150
534
567
153
155
553
587
143
145
513
541
153
155
526
555
158
160
544
574
135
137
550
583
144
146
564
598
149
151
584
619
137
139
536
565
147
149
550
579
152
154
569
599
135
136
558
586
144
145
572
601
149
150
592
622
137
139
526
554
147
149
539
568
152
154
558
588
133
135
570
603
142
144
585
618
147
149
605
640
137
138
553
580
146
148
567
595
151
153
587
616
132
134
553
583
141
143
567
598
146
148
587
619
Manual 2100-581D
Page
19 of 26

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents