Table 5 Recommended Airflow; Table 6 Indoor Blower Performance; Table 7 Maximum Esp Electric Heat Only - Bard W17A2-A Installation Instructions Manual

Wall mounted packaged
Table of Contents

Advertisement

W17A, W17L
W18A, W18L
W24A, W24L
W30A, W30L
W36A, W36L
W42A, W42L
W48A, W48L
W60A, W60L
W70A, W70L
* Rated CFM and ESP on factory speed connection.
W17/18
W24
Speed
High
Low
Single
ESP
Dry
Wet
Dry
Wet
Dry
(Inch
Coil
Coil
Coil
Coil
Coil
H20)
0.0
1045 1025
760
745
990
0.1
1010 970
730
715
945
0.2
940
905
700
685
890
0.3
860
830
670
655
820
0.4
780
750
610
595
735
0.5
665
640
485
455
605
W17A/L,
Model
W18A/L,
W24A/L
Outlet
FRONT
Speed
Single
-A0Z
.50
-A04
-A05
.50
-A08
.50
-A10
-A15
-A20
-B0Z
.50
-B06
.50
-B09
-B15
-B18
-C0Z
-C06
-C09
-C15
Values shown are for units equipped with standard 1" throwaway filter or 1" washable filter.
Derate ESP by .15 for 2" pleated filters.
Manual 2100-581D
Page
22 of 26
Recommended Airflow
Nominal
Nominal
Model
Rated
Rated
CFM *
ESP *
600
.40
550
.45
800
.30
1000
.30
1100
.20
1400
.45
1550
.30
1700
.40
1700
.20
Indoor Blower Performance
W30
High
Low
High
Wet
Dry
Wet
Dry
Wet
Dry
Coil
Coil
Coil
Coil
Coil
Coil
970
1370 1285
910
885
1415 1275
925
1305 1225
885
860
1350 1215
870
1225 1135
850
815
1265 1125
800
1115 1020
790
755
1190 1060
720
1005
910
695
660
1085
590
865
775
590
560
970
Maximum ESP of Operation
Electric Heat Only
W30A/L, W36A/L
FRONT
High
Low
High
.50
.50
.50
.50
.50
.50
.50
.50
.50
.45
.50
.40
.35
.50
.50
.50
.50
.40
.50
.50
.45
.45
.30
.50
.50
.50
.50
.50
.50
.40
.45
.45
.35
TABLE 5
Recommended
Factory Speed
Airflow Range
550 - 725
550 - 725
700 - 950
850 - 1300
930 - 1350
1600 - 1150
1750 - 1285
1950 - 1375
1950 - 1375
TABLE 6
W36
W42/48
Low
High
Low
Wet
Dry
Wet
Dry
Wet
Dry
Coil
Coil
Coil
Coil
Coil
Coil
955
925
1850 1800 1605 1555 2080 2015 1505 1460 2050 1845 1490 1400
945
915
1775 1725 1545 1500 2020 1960 1450 1405 1970 1770 1425 1340
925
900
1685 1640 1460 1415 1925 1865 1395 1355 1905 1700 1375 1295
875
850
1590 1550 1390 1345 1870 1815 1340 1300 1830 1645 1225 1150
975
780
755
1495 1460 1310 1270 1755 1705 1225 1185 1725 1550 1140 1070
865
640
615
1400 1365 1225 1185 1660 1610 1125 1085 1500 1350 1050
TABLE 7
W42A/L, W48A/L
TOP
FRONT
Low
High
.50
.50
.45
.50
.35
.50
.50
.50
.50
.50
.40
.50
.50
.50
.50
.50
.40
.50
.50
Connection
Low
Low
Single
High
High
High
High
High
High
W60
High
Low
High
Wet
Dry
Wet
Dry
Wet
Dry
Coil
Coil
Coil
Coil
Coil
Coil
W60A/L, W70A/L
FRONT
Low
High
Low
.50
.50
.50
.50
.50
.50
.50
.50
.50
.50
.50
.50
.45
.50
.40
.50
.50
.50
.50
.50
.50
.50
.50
.50
.50
.50
.50
.50
.50
.50
.50
.50
.50
.50
.50
.50
W70
Low
Wet
Dry
Wet
Coil
Coil
Coil
985

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents