Daikin Altherma 3 R F User Reference Manual

Daikin Altherma 3 R F User Reference Manual

Hide thumbs Also See for Altherma 3 R F:
Table of Contents

Advertisement

Quick Links

EBVZ16S18DJ6V
EBVZ16S23DJ6V
EBVZ16S18DJ9W
EBVZ16S23DJ9W
User reference guide
Daikin Altherma 3 R F

Advertisement

Table of Contents
loading

Summary of Contents for Daikin Altherma 3 R F

  • Page 1 User reference guide Daikin Altherma 3 R F EBVZ16S18DJ6V EBVZ16S23DJ6V EBVZ16S18DJ9W EBVZ16S23DJ9W...
  • Page 2: Table Of Contents

    Symptom: You are feeling too cold (hot) in your living room..................56 Symptom: The water at the tap is too cold........................56 Symptom: Heat pump failure ............................57 User reference guide EBVZ16S18+23DJ Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 3 9 Relocation Overview: Relocation ..............................59 10 Disposal 11 Glossary 12 Installer settings: Tables to be filled in by installer 12.1 Configuration wizard............................... 62 12.2 Settings menu ................................. 63 EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 4: About This Document

    Format: Paper (in the box of the indoor unit) + Digital files on http:// www.daikineurope.com/support-and-manuals/product-information/ Latest revisions of the supplied documentation may be available on the regional Daikin website or via your installer. The original documentation is written in English. All other languages are translations. EBVZ16S18+23DJ...
  • Page 5: Meaning Of Warnings And Symbols

    About this document Daikin Residential Controller app If set up by your installer, you can use the Daikin Residential Controller app to control and monitor the status of your system. For more information, see: http://www.onlinecontroller.daikineurope.com/ Breadcrumbs Breadcrumbs (example: [4.3]) help you to locate where you are in the menu structure of the user interface.
  • Page 6 Example: " 1–3 Figure title" means "Figure 3 in chapter 1". Indicates a table title or a reference to it. Example: " 1–3 Table title" means "Table 3 in chapter 1". EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 7: User Safety Instructions

    Do NOT place any objects containing water on the unit. CAUTION ▪ Do NOT place any objects or equipment on top of the unit. ▪ Do NOT sit, climb or stand on the unit. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 8: Instructions For Safe Operation

    Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommended by the manufacturer. ▪ Be aware that the refrigerant inside the system is odourless. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 9 Reason: Refrigerant might leak into the water circuit, and subsequently into the room when you purge air from the heat emitters or collectors. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 10: About The System

    Domestic hot water (DHW) tank d User interface of the indoor unit e Dedicated Human Comfort Interface (BRC1HHDA used as room thermostat) f Underfloor heating g Radiators, heat pump convectors, or fan coil units EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 11: Quick Guide

    Operation > Space heating/cooling), room frost protection operation –if enabled– can still activate. However, for leaving water temperature control and external room thermostat control, the protection is NOT guaranteed. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 12 You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature. 1 Go to [2]: Main zone or [3]: Additional zone. Main zone Additional zone EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 13 X2. X1, X2 Outdoor ambient temperature Y1~Y4 Desired leaving water temperature a WD curve before changes b WD curve after changes c Slope d Offset EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 14 More information For more information, see also: ▪ "5.4 Turning operation ON or OFF" [  24] ▪ "5.6 Space heating/cooling control" [  26] ▪ "5.8 Preset values and schedules" [  34] ▪ "5.9 Weather-dependent curve" [  43] EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 15: Domestic Hot Water

    [5.3] and Reheat setpoint [5.4]. More information For more information, see also: ▪ "5.4 Turning operation ON or OFF" [  24] ▪ "5.7 Domestic hot water control" [  30] ▪ "5.8 Preset values and schedules" [  34] EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 16: Operation

    Dials and buttons You use the dials and buttons: ▪ To navigate through the screens, menus and settings of the LCD screen ▪ To set values EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 17 : Turn the right dial. Navigate through the possible values and settings. ▪ : Press the right dial. Confirm your choice and go to the next menu item. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 18: Menu Structure: Overview User Settings

    (*) Only applicable when EKHVCONV* is installed (**) Only accessible by installer (***) Only applicable when WLAN is installed INFORMATION Depending on the selected installer settings and unit type, settings will be visible/ invisible. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 19: Possible Screens: Overview

    26 Feb 2019 22:19 Possible actions on this screen Go through the list of the main menu. Go to the main menu screen. Enable/disable breadcrumbs. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 20 Quiet mode active Outdoor unit Indoor unit / domestic hot water tank Floor-standing indoor unit with integrated tank Wall-mounted indoor unit Wall-mounted indoor unit with separated tank Water pressure EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 21 "8.1 To display the help text in case of a malfunction" [  55] for more information. If the corresponding operation (for example: space heating) is not active, the circle is greyed out. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 22: Main Menu Screen

    Gives access to user settings such as holiday User settings mode and quiet mode. Displays data and information about the Information indoor unit. Installer settings Restriction: Only for the installer. Gives access to advanced settings. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 23: Setpoint Screen

    Adjust and automatically apply the desired temperature. Item Description Minimum temperature limit Fixed by the unit Restricted by the installer Maximum temperature limit Fixed by the unit Restricted by the installer EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 24: Detailed Screen With Values

    Space heating/cooling operation a Space heating/cooling operation ON b Space heating/cooling operation OFF EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 25: To Turn On Or Off

    1 Go to [C.3]: Operation > Tank. Operation Space heating/cooling Tank 2 Set operation to On or Off. 5.5 Reading out information To read out information 1 Go to [8]: Information. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 26: Space Heating/Cooling Control

    To determine if a heating/cooling heat pump model is installed 1 Go to [4]: Space heating/cooling. 2 Check if [4.1] Operation mode is listed and editable. If so, a heating/cooling heat pump model is installed. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 27 Example: Changeover restrictions When Restriction During cold season. Heating only Example: October, November, December, January, February and March. During warm season. Cooling only Example: June, July and August. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 28: Determining Which Temperature Control You Are Using

    5.6.4 To change the desired room temperature During room temperature control, you can use the room temperature setpoint screen to read out and adjust the desired room temperature. 1 Go to [1]: Room. Room EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 29: To Change The Desired Leaving Water Temperature

    You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature. 1 Go to [2]: Main zone or [3]: Additional zone. Main zone Additional zone EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 30: Domestic Hot Water Control

    5.7.1 About domestic hot water control Depending on the DHW tank mode (installer setting), you use a different domestic hot water control: ▪ Reheat only ▪ Schedule + reheat ▪ Schedule only EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 31: Reheat Mode

    In reheat mode the DHW tank continuously heats up to the temperature shown on the home screen (example: 50°C) when the temperature drops below a certain value. 60°C 50°C 40°C 15°C 00:00 07:00 14:00 21:00 DHW tank temperature t Time EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 32: Scheduled Mode

    (example: 45°C). This ensures that a minimum amount of hot water is available at all times. Example: 60°C 50°C 45°C 35°C 15°C 00:00 07:00 14:00 21:00 Domestic hot water tank temperature t Time EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 33: To Change The Domestic Hot Water Temperature

    You cannot wait for the next scheduled action to heat up the domestic hot water tank. Then you can activate powerful operation. The domestic hot water tank will start heating up the water to the Comfort temperature. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 34: Preset Values And Schedules

    Quiet/More quiet/Most quiet. 5.8.2 Using and programming schedules About schedules Depending on your system layout and installer configuration, schedules for multiple controls may be available. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 35 This entry shows you where to activate it. ▪ Possible actions: Actions you can use when programming a schedule. For most schedules, you can program up to 6 actions per day. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 36 "To set the space operation mode" [  27]. cooling > Operation mode schedule Schedule (per month) for when to operate the unit in heating mode and when in cooling mode. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 37: Schedule Screen: Example

    5.8.3 Schedule screen: Example This example shows how to set a room temperature schedule in heating mode for the main zone. INFORMATION The procedures to program other schedules are similar. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 38 3 Select OK to confirm. To clear the content of a day schedule 1 Select the day of which you want to clear the content. For example Friday User defined 1 EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 39 Monday is the first day you programmed. Thus, the last programmed action is valid up to the first action of next Monday. To copy the schedule to the other weekdays 1 Select Monday. User defined 1 EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 40 3 Use the left dial to select an entry and edit the entry with the right dial. 8:00 21°C 23:00 18°C --:-- 4 Confirm the changes. 5 Select Saturday. 6 Select Copy. 7 Select Sunday. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 41: Setting The Energy Prices

    ▪ 3 electricity price levels ▪ a weekly schedule timer for electricity prices. Example: How to set the energy prices on the user interface? EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 42 NOTICE Make sure to modify the setting of the energy prices at the end of the incentive period. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 43: Weather-Dependent Curve

    Because it reacts more quickly, it prevents high rises and drops of the indoor temperature and water temperature at tap points. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 44: 2-Points Curve

    See "5.9.4 Using weather-dependent curves" [  46]. 5.9.2 2-points curve Define the weather-dependent curve with these two setpoints: ▪ Setpoint (X1, Y2) ▪ Setpoint (X2, Y1) Example EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 45: Slope-Offset Curve

    Examples Weather-dependent curve when slope is selected: Weather-dependent curve when offset is selected: EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 46: Using Weather-Dependent Curves

    Confirm changes and return to the submenu. 5.9.4 Using weather-dependent curves Configure weather-dependent curves as following: To define the setpoint mode To use the weather-dependent curve, you need to define the correct setpoint mode: EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 47 You cannot configure the curve with temperatures that are higher or lower than the set maximum and minimum setpoints for that zone or for the tank. When the maximum or minimum setpoint is reached, the curve flattens out. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 48: Other Functionalities

    ↑ ↓ ↑ ↓ ↓ ↓ ↓ ↓ "5.9.2 2-points curve" [  44]. 5.10 Other functionalities 5.10.1 To configure time and date 1 Go to [7.2] User settings > Time/date. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 49: Using Quiet Mode

    Setting the starting date and ending date of your holiday. Activating the holiday mode. To check if holiday mode is activated and/or running is displayed on the home screen, holiday mode is active. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 50: Using Wlan

    About the WLAN cartridge or WLAN module The WLAN cartridge or WLAN module (only one of the two needed) connects the system to the internet. As user you can then control the system via the Daikin Residential Controller app. This needs the following components in case of WLAN cartridge:...
  • Page 51 The Daikin Residential Controller app needs to be installed on the user's smartphone. See: http://www.onlinecontroller.daikineurope.com/ Configuration To configure the Daikin Residential Controller app, follow the in-app instructions. While doing this, the following actions and information are needed on the user interface: [D] Wireless gateway...
  • Page 52 [D.6] Cloud connection: Read out the status of the connection to the cloud: 1 Go to [D.6]: Wireless gateway > Cloud connection. 2 Read out the connection status: ▪ Not connected ▪ Connected EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 53: Energy Saving Tips

    ▪ Program to turn ON the domestic hot water pump ONLY during periods of the day when instant hot water is necessary. Example: In the morning and evening. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 54: Maintenance And Service

    Turn off any combustible heating devices, ventilate the room, and contact the dealer where you purchased the unit. Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 55: Troubleshooting

    Conditions: The user permission level is set to advanced end user. 1 Go to [8.2]: Information > Malfunction history. You see a list of the most recent malfunctions. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 56: Symptom: You Are Feeling Too Cold (Hot) In Your Living Room

    DHW tank to a preset value (Eco setpoint = lower tank temperature) during the day. "5.8.2  Using programming schedules"  [   34] and "5.8.3  Schedule screen: Example" [  37]. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 57: Symptom: Heat Pump Failure

    To be performed by the installer: Perform hydraulic balancing to assure that the flow is correctly distributed between the emitters. hydraulic balancing sufficient, change pump limitation settings ([9-0D] and [9-0E] if applicable). EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 58 If yes, make sure that the room where you want to purge air is sufficiently ventilated. Reason: Refrigerant might leak into the water circuit, and subsequently into the room when you purge air from the heat emitters or collectors. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 59: Relocation

    If you want to relocate parts of your system, contact your installer. You can find the contact/helpdesk number via the user interface. 1 Go to [8.3]: Information > Dealer information. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 60: Disposal

    Do NOT try to dismantle the system yourself: dismantling of the system, treatment of the refrigerant, oil and other parts MUST comply with applicable legislation. Units MUST be treated at a specialised treatment facility for reuse, recycling and recovery. EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 61: Glossary

    Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Field supply Equipment NOT made by Daikin that can be combined with the product according to the instructions in the accompanying documentation.
  • Page 62: Installer Settings: Tables To Be Filled In By Installer

    WD curve type [3.C] (read only) Tank Heat up mode [5.6] Comfort setpoint [5.2] Eco setpoint [5.3] Reheat setpoint [5.4] Setpoint mode [5.B] WD curve type [5.E] (read only) EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 63: Settings Menu

    Installer settings: Tables to be filled in by installer 12.2 Settings menu Setting Fill in… Main zone Thermostat type [2.A] Additional zone (if applicable) Thermostat type [3.A] Information Dealer information [8.3] EBVZ16S18+23DJ User reference guide Daikin Altherma 3 R F 4P643608-1 – 2021.09...
  • Page 64 4P643608-1 2021.09 Verantwortung für Energie und Umwelt...

This manual is also suitable for:

Ebvz16s18dj6vEbvz16s23dj6vEbvz16s18dj9wEbvz16s23dj9w

Table of Contents