Omron NA5-15W101S-V1 User Manual page 97

Programmable terminals
Table of Contents

Advertisement

When Connected to an NJ-series CPU Unit
System configuration element
CPU Rack
EtherCAT Slaves (Sysmac devices)
EtherCAT Slave Ter-
minals
*1. You cannot display or delete events in the error history (upper four digits of event code are 0000 hex) in a
CJ-series Special Unit mounted on an NJ-series CPU Unit.
*2. Supported in runtime version 1.03 or higher.
*3. Event logs for individual units cannot be cleared.
*4. Events are not displayed for some NX Units. If an error occurs in an NX Unit that does not display events, an
NX Unit Minor Fault event will occur in the EtherCAT Coupler Unit and the unit number of the NX Unit in which
the error occurred will be given in the attached information.
*5. Errors that occur on a specific NX Unit cannot be cleared separately.
*6. It might be necessary to reset errors in Safety Control Units with a safety program. Refer to the NX-series Safe-
ty Control Unit User's Manual (Cat. No. Z930) for details on resetting errors in Safety Control Units.
When Connected to an NY-series CPU Unit
System configuration element
CPU Unit
EtherCAT Slaves (Sysmac devices)
EtherCAT Slave Ter-
minals
*1. Supported in runtime version 1.06 or higher.
*2. Event logs for individual units cannot be cleared.
*3. Events are not displayed for some NX Units. If an error occurs in an NX Unit that does not display events, an
NX Unit Minor Fault event will occur in the EtherCAT Coupler Unit and the unit number of the NX Unit in which
the error occurred will be given in the attached information.
*4. Errors that occur on a specific NX Unit cannot be cleared separately.
*5. It might be necessary to reset errors in Safety Control Units with a safety program. Refer to the NX-series Safe-
ty Control Unit User's Manual (Cat. No. Z930) for details on resetting errors in Safety Control Units.
NA-series Programmable Terminal Hardware(-V1) User's Manual (V125)
Displaying
errors
CPU Unit
CJ-series Units
EtherCAT Cou-
pler Units
NX Units
Partially appli-
cable
Displaying
errors
EtherCAT Cou-
pler Units
NX Units
Partially appli-
cable
Troubleshooter functions
Clearing
Displaying
errors
Applicable
Applicable
Applicable
Applicable
Applicable
Applicable
*5 *6
Applicable
Applicable
*4
Troubleshooter functions
Clearing
Displaying
errors
Applicable
Applicable
Applicable
Applicable
Applicable
*4 *5
Applicable
Applicable
*3
4 System Program
Clearing error
error logs
logs
*1
Partially applicable
*2
*2 *3
Applicable
*2
*2 *3
Applicable
*2
*2 *3
Applicable
Clearing error
error logs
logs
*1
*1 *2
Applicable
*1
*1 *2
Applicable
*1
*1 *2
Applicable
4 - 15