Elements of each column are shown below. Rows including the initial row are handled as data and
up to 16 rows are loaded.
Column
Number
1
2
3
 Display Filter Settings
Specify the variables not to be displayed on the Safety Monitor.
1
2
No.
1
Output from Safety CPU
2
Variables List
3
OK
4
Cancel
5
Input to Safety CPU
NA-series Programmable Terminal Hardware(-V1) User's Manual (V125)
Item
PDF File Name
Specifies the name of the PDF file to be displayed. Extensions cannot be
omitted.
If this column is omitted, it causes an error.
Target Controller
Specifies the name of the controller for which the specified PDF file is
Name
displayed.
If this column is omitted, it causes an error.
Safety Signature
Specifies the safety signature for the safety controller connected to the
controller specified in Target Controller Name.
When a value is set in this column, the set value and the safety signature
for the safety controller to be displayed must match in order to execute
PDF Display. When this column is omitted, PDF Display is executed
unconditionally.
3
Item
Description
4
Description
Changes the variables displayed in Variables List to outputs.
Displays a list of applicable variables as well as comments.
Deselected variables are not displayed on the Safety Monitor.
This button applies the settings.
Discards the settings.
Changes the variables displayed in Variables List to inputs.