Nortel 201i Maintenance And Diagnostics page 38

Callpilot
Hide thumbs Also See for 201i:
Table of Contents

Advertisement

Troubleshooting your CallPilot system
Status code
NT
CDLN
C:01
C:02
38
Operation description
The operating system start sequence
started
Note: If the CallPilot server software
is not installed, the HEX display
remains at NT. (This can occur if you
are performing a system rebuild.)
During CallPilot software
installation, the 8051 device driver is
copied to the operating system, at
which point the HEX display shows
CDLN.
8051 device driver on the operating
system has started; beginning of
Cardlan interface communication
(DS30x interface initialization)
The system controller communicates
with the switch, indicating that two
cards are installed, and waits for
switch acknowledgement.
Initialization of the first DS30x
interface
Initialization of the second DS30x
interface
Standard 1.05
Failure code
P:XX
Note: For a description,
see "P:XX failure codes"
on page 39.
CDLN
Neither DS30x interface
was initialized (both
failed).
C:01
Initialization of the first
DS30x interface failed.
The second DS30x
interface is OK.
C:02
Initialization of the second
DS30x interface failed.
The first DS30x interface
is OK.